To investigate whether Budesonide/Formoterol (Symbicort ®) therapy can improve heart function at rest by decreasing lung hyperinflation in patients with COPD (Chronic Obstructive Pulmonary Disease).
Patients with moderate to advanced COPD are known to have static hyperinflation (at rest) as a consequence of expiratory flow limitation. Hyperinflation is easily detected by measuring lung volumes during standard pulmonary function testing. Decreased Inspiratory Capacity (IC) secondary to hyperinflation has been described as a predictor of mortality in COPD, and as a limiting factor for the maximal tidal volume attained during exercise. Hyperinflation has been linked to a low cardiac output in part by limiting left ventricular ejection fraction during exercise. Treatment with inhaled anticholinergic agents or long-acting beta agonists (LABA) and combination of the LABA formoterol and budesonide has been shown to improve IC and decrease lung hyperinflation. Bronchodilators have been shown to improve exercise endurance in COPD when combined with pulmonary rehabilitation, however the exact mechanism: improvement of lung mechanics and /or improvement in cardiac function is not well known. Impedance cardiography (ICG) has emerged as a method to measure cardiac output without the need for invasive devices. Cardiac output measurement by impedance cardiography (CO-ICG) is a valid and reproducible method. It has been shown to have good correlation with thermodilution and the direct Fick method for the measurement of stroke volume and cardiac output. In addition, the oxygen pulse, easily obtained by dividing the measured oxygen uptake by the heart rate (VO2/HR) provides an adequate reflection of cardiac stroke volume when the systemic extraction of oxygen is stable. This method has been used to evaluate the effect of static and dynamic hyperinflation on cardiac function. This pilot study is designed to be a single center (Brigham and Women's Hospital), randomized, placebo-controlled, double blind, crossover study of 14 patients (male and female 40 to 80 years old) with COPD and static hyperinflation. The primary endpoint is the measurement of stroke volume, cardiac output and oxygen pulse at rest before and after the administration of budesonide/formoterol compared to placebo.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
5
Budesonide/ formoterol (B/F) 160/4.5 mcg per activation. Subject who met inclusion criteria will be have at each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs of either Budesonide/formoterol (B/F) 160/4.5 mcg per activation (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.
Each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs of placebo (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.
Brigham and Women's Hospital
Boston, Massachusetts, United States
Cardiac Output
Impedance cardiography (ICG) (BioZ Dx ICG machine, by CardioDynamics) was used to measure cardiac output without the need for invasive devices. Cardiac output measurement by impedance cardiography (CO-ICG) is a plethysmography technique using sensors to detect the properties of the blood flow in the thorax. All subjects had on each visit a baseline measurement at rest and then 45 minutes after intervention (Budesonide/formoterol or Placebo). Measurement were performed at rest for 5 minutes to obtain a steady state and the last 2 minutes were taken for analysis as an averaged value labeled as pre and post intervention. For the analysis we calculated the difference from pre and post intervention at each visit. Paired t-test was used to compare the mean+/- SD of the pre and post difference when taking the study drug vs placebo.
Time frame: Change from Baseline and at 45 minutes after administration of study medication or placebo
Lung Hyperinflation
Evaluation of lung hyperinflation as determined by Pulmonary function test where Inspiratory Capacity (IC) before and 45 minutes after the administration of the budesonide/formoterol or placebo.
Time frame: Change from Baseline and after 45 minutes after administration of study medication or placebo
Evaluation of O2 Pulse
Evaluation of O2 Pulse is the measurement of oxygen consumption pre and post intervention
Time frame: Change from Baseline and 45 minutes after administration of study medication or placebo
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.