This retrospective study comprised patients with cataract, corneal astigmatism, and motivation for spectacle independence. In all cases, a multifocal and monofocal Intraocular Lens was been implanted in the capsular bag. Three months postoperatively, distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity was evaluated. A patient-satisfaction and visual phenomena questionnaire was also been administered.
Postoperative evaluation was performed at 3 months. The uncorrected and corrected distance visual acuity were assessed using the 100% contrast Early Treatment Diabetic Retinopathy Study chart, uncorrected intermediate visual acuity at 70 cm, and uncorrected near visual acuity at 40 cm; a binocular defocus curve was constructed using the ETDRS chart at 4 m and adding to the patient's manifest refraction +2.50 to -5.00 D sphere in 0.50 increments. The cylinder axis of the Intraocular lens (IOL) was measured at the slitlamp using the beam protractor after full mydriasis. The mean of the absolute values of degrees the intraocular lens was off axis was determined. Contrast sensitivity was measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree. The background illumination of the translucent chart does not depend on room lighting. All measurements were obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations were performed unilaterally at a distance of 2.5 m with Best-corrected visual acuity (BCVA) and an undilated pupil. All measurements were performed under the same conditions. Patient satisfaction and quality of life were assessed by a simple questionnaire. Patients were interviewed 3 months postoperative. Patients were asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.
Study Type
OBSERVATIONAL
Enrollment
80
University of Sao Paulo
São Paulo, São Paulo, Brazil
Visual Performance in Pseudophakic Patients With Different Intraocular Lens
Postoperative evaluation was been performed at 6 months. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) was assessed using the 100% contrast ETDRS chart; a binocular defocus curve was constructed using the ETDRS chart at 4 m.
Time frame: 6 months postoperative
Contrast sensitivity
Contrast sensitivity was measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd). The background illumination of the translucent chart does not depend on room lighting. All measurements was obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations was performed unilaterally at a distance of 2.5 m with BCVA and an undilated pupil. All measurements was performed under the same conditions.
Time frame: 6 months
Patient satisfaction
Patient satisfaction and quality of life was assessed by a simple questionnaire. Patients was interviewed 6 months postoperative. Patients was asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.
Time frame: 6 months