The overall sensitivity and specificity of 11C-MET PET/CT is superior to 18F-FDG PET/CT and conventional SPECT-CT for the detection of abnormal parathyroid glands.
STUDY OBJECTIVES Primary: To compare the accuracy, sensitivity and specificity of 11C-methionine (MET) PET/CT and 99mTc-MIBI SPECT-CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism. Secondary:To compare the accuracy, sensitivity and specificity of 11C-MET and 18F-FDG PET/CT scans in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism. STUDY DESIGN A phase II diagnostic imaging, single-centre study to compare the accuracy of 11C-MET PET/CT with standard 99mTc-MIBI SPECT-CT and with 18F-FDG PET/CT imaging in patients with primary hyperparathyroidism. STUDY POPULATION Number of Subjects: 50 patients Number of groups: 1: 50 with primary hyperparathyroidism. Age/Gender: Age greater than or equal to 19 years / Male and Female Study specific requirements: Subjects with clinically suspected primary hyperparathyroidism who require 99mTc-MIBI SPECT-CT parathyroid imaging. INVESTIGATIONAL PRODUCT Product: 11C-Methionine Route of administration: Intravenous Dosage(s) and frequency: Radioactive dose of 11C-Methionine of 6 MBq per kilogram body weight per injection (maximum dose of 555 MBq); one injection per patient. COMPARATOR PRODUCTS Product: 99mTc-Methoxyisobutylisonitrite; 18F-Fluorodeoxyglucose Route of administration: Intravenous Dosage(s) and frequency: (1) Radioactive dose of 99mTc-Methoxyisobutylisonitrite of 555 - 740 MBq per injection; one injection per patient. (2) Radioactive dose of 18F-Fluorodeoxyglucose of 296 - 521 MBq per injection; one injection per patient. EVALUATION CRITERIA Efficacy: The comparison of the accuracy, sensitivity, and specificity of 11C-MET PET/CT with 99mTc-MIBI SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism. Safety: Vital signs before and following 11C-MET administration; adverse events collection.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
50
PET with the radiopharmaceutical carbon-11 methionine (11C-MET) has been considered to improve diagnosis due to a superior spatial resolution and higher specificity compared to other radiotracers such as 18F-FDG. For the 11C-MET PET/CT, the patient will receive an intravenous bolus injection of 11C-MET as manufactured at the BCCA production facility at a dose of 6 (0.16 mCi) MBq per kilogram but not to exceed 555 MBq (15 mCi).
For PET/CT scans, the patient will first receive an intravenous bolus injection of 18F-FDG as manufactured at the BCCA production facility in a dose determined by body weight but not to exceed 521 MBq (14.1 mCi). Our standard adult prescription (70kg adult) for 18F-FDG is 296 MBq (8.0 mCi). The target dose for body scans is increased by 59.2 MBq (1.6 mCi) for every 20 kg increase in body weight to a maximum target dose of 474 MBq (12.8 mCi).
British Columbia Cancer Agency
Vancouver, British Columbia, Canada
RECRUITINGTo compare the sensitivity of 11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
Sensitivity is the percentage of patients that were correctly identified to have an abnormal parathyroid gland by the imaging studies.
Time frame: Patient will undergo the scans at baseline
To compare the specificity of11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
Specificity is defined as the percentage of patients that were correctly rejected for having an abnormal parathyroid gland by the imaging studies.
Time frame: Patient will undergo the scans at baseline
To evaluate the safety profile of 11C-MET PET/CT.
All adverse events will be recorded. An Adverse Event (AE) is any untoward, undesired, unplanned medical occurrence in a participant and does not necessarily have a causal relationship with the study intervention. Expected adverse events from PET/CT scans include bruising, bleeding or infection at the site of intravenous radiotracer injection. Other expected adverse events include feeling of discomfort or claustrophobia from being in the scanner.
Time frame: Up to 2 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
For the SPECT-CT scan, each injection of intravenous 99mTc-MIBI is dosed at a maximum of 20 mCi (740MBq), as per usual standard of care. The energy window of each scan is at 140 keV, consistent with the standard of SPEC-CT imaging techniques.