The incidence of ventral hernias has remained inappropriately high. Any innovation in order to reduce this incidence would be simply cost-effective. Although there is still some concern about the use of mesh in clean-contaminated or contaminated surgery, based in our experimental studies, we plan to use a mesh in the primary closure of abdominal incision to prevent incisional hernias. The investigators propose a clinical trial to assess a model to prevent the incisional hernia after laparotomy to treat colorectal carcinoma is scheduled. A simple randomization is scheduled: in the intervention group a prefascial large-pore low-weight 5 cm wide polypropylene mesh is fixed covering the midline closure; in the control group a conventional closure with a running suture of long-term absorbable material with a suture/wound length ratio 4:1. The sample size was calculated with an estimated incidence of ventral hernia of 25% in the control group and 10% in the intervention group, 0,05 alfa and a 0,15 beta error. The main goal is the appearance of a ventral hernia after 24 months of follow-up. Other outcomes are wound complications and morbidity. Exclusion criteria are adult patients with a previous ventral hernia, estimated survival of less than 6 months or hemodynamic instability during surgery. The diagnosis of ventral hernia will be assessed by clinical exploration on 3,6,12,18 and 24 months and abdominal CT controls at 6,12, and 24 months. The study will be statistically evaluated with SPSS 18.0.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
112
Closure of midline laparotomy using a prophylactic mesh. The midline is closed with a running absorbable monofilament suture with a suture/wound length ratio 4:1. The material is a monofilament uncoated suture made of poly-4hiydroxybutirate (Monomax, B.Braun) USP 1. Then, a prefascial large-pore low-weight 5 cm wide polypropylene mesh (Optilene Mesh Elastic, B.Braun) is fixed covering the midline closure. The mesh is fixed in the prefascial plane with absorbable monofilament interrupted sutures, USP 2/0.
Closure of midline laparotomy without mesh. The laparotomy is closed with a running absorbable monofilament suture with a suture/wound length ratio 4:1. The material is a monofilament uncoated suture made of poly-4hiydroxybutirate (Monomax, B.Braun) USP 1.
Henares University Hospital
Coslada, Madrid, Spain
Compare the incidence of ventral hernia between the 2 groups
Compare the incidence of ventral hernias at the end of the second year follow-up in patients operated for laparotomy using two different methods of abdominal wall closure: one with mesh reinforcement and another one with no mesh reinforcement
Time frame: 24 months
Incidence of superficial surgical site infection
Compare the incidence of superficial surgical site infection between the 2 groups
Time frame: 30 days
Incidence of deep surgical site infection
Compare the incidence of deep surgical site infection between the 2 groups
Time frame: 30 days
Seroma
Incidence of postoperative seroma
Time frame: 30 days
Postoperative complications
Register of postoperative complications, including pulmonary, fistula and postoperative ileum
Time frame: 30 days