To assess the feasibility of a new neuromonitoring system (NeMoSystem including NeMo Probe and NeMo Patch) and the accuracy of the measurement values (cerebral blood flow (CBF); cerebral blood volume (CBV)) obtained.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
16
A plaster based patch (NeMo Patch) and a combined probe for ICP monitoring and near infrared spectroscopy (NIRS) are applied as sensors. Data are collected by a NIRS instrument (NeMo Control Unit)
Dept. of Neurosurgery, Medical University of Graz
Graz, Austria
Neurointensive Care Unit, University Hospital Zurich
Zurich, Switzerland
To assess the feasibility of the neuromonitoring system and the accuracy of the measurement values.
Feasibility: User acceptance: For NeMo Probes in comparison to conventional probes for intracranial pressure (ICP-) monitoring; for NeMo Patch in comparison to patches for electroencephalography (EEG) monitoring. Detailled evaluation of user acceptance: * Incidence of concerns of users in relation to the installation, function and removal of the NeMo System (= NeMo Probe, NeMo Patch, NeMo Control Unit and NeMo Software pre-installed on a Medical PC) * User-friendliness with a 3-graded scale (equal, better, worse) compared to conventional devices Accuracy of measurements: -Patients: Results from repeated measurements of mean transit time of ICG (mttICG), cerebral blood flow (CBF) and cerebral blood volume (CBV) Safety parameters: Incidence of complications (infections, brain tissue damage, haemorrhage) compared to historical series (patches for EEG and for BIS measurements; conventional probes for ICP monitoring)
Time frame: Day 28 after removal of medical device
To demonstrate the ability of the neuromonitoring system to detect secondary ischemic events in patients with severe subarachnoid haemorrhage (SAH) or severe traumatic brain injury (TBI).
Results concerning sensitivity and specificity to detect symptomatic vasospasm in patients with subarachnoid hemorrhage (SAH) (correlation of events with CBF values \< 15 ml/100g/min with defined criteria for vasospasm) Results concerning sensitivity and specificity to detect secondary infarctions and critical ICP values in TBI patients (correlation of events with CBF values \< 15 ml/100g/min with defined criteria for secondary infarction) Results from repeated measurements for the difference between measurement values obtained with the NeMo Patch and the NeMo Probe, quantified with mathematical models
Time frame: Day 28 after removal of medical device