The purpose of this study is to investigate the appropriate window setting of chest computed tomography to select a correct size of double-lumen endobronchial tube.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
228
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 1000 HU and level -450 HU.
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 400 HU and level 25 HU.
Seoul National University Hospital
Seoul, South Korea
Air-leak at deflation of bronchial cuff
Time frame: An expected average of 10 min after double lumen tube intubation
Air-tight seal below resting volume of bronchial cuff
Time frame: An expected average of 10 min after double lumen tube intubation