During percutaneous coronary interventions standard operator radio-protection is generally ensured using a lead apron, a thyroid lead collar, low leaded flaps, an upper mobile leaded glass suspended from the ceiling and leaded glasses. Previous studies showed that adding a bismuth-barium radiation shield drape on the patient right arm or using a pelvic lead shield on the patient, the radiation dose adsorbed by operators was significantly reduced even if was higher compared to transfemoral approach. No studies evaluated the effect of both adjunctive shields placed in the same patient. Aim of our randomized study is to evaluate if the combination of a shield drape on the patient right arm and a pelvic lead shield during transradial percutaneous coronary procedures may reduce the radiation dose adsorbed by operators compared to the use of only one shield or none. All patients who underwent to percutaneous coronary diagnostic or interventional procedures will be enrolled in this randomized study. Eligible patients will be randomized (using a computer generated randomization sequence) in 4 groups: 1. use of a pelvic shield drape 2. use of a shield drape on the patient right arm 3. use of a pelvic shield drape and a shield drape on the patient right arm 4. Any adjunctive shield drape (only standard radio-protection) For each group a further internal randomization will be performed in order to compare the right or left radial transradial approach. Each operator will be equipped with dedicated dosimeters placed at left wrist and at thorax level outside the lead apron. Since December 2013 the operators are equipped with a further dosimeter at head level. Primary end-point of the study is the radiation dose adsorbed at wrist and thorax by operators and detected by the electronic dosimeters. Secondary end-point are: 1. Radiation dose adsorbed by operators according to the radial access (right versus left) 2. Radiation dose adsorbed by the patients 3. Radiation dose adsorbed at head level.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
452
Diagnostic coronary angiography
Percutaneous coronary intervention
Right transradial access
Left transradial access
Ospedale Sandro Pertini - ASL RMB- UOSD Emodinamica
Rome, Rome, Italy
Radiation dose adsorbed by operators
Primary end-point of the study is the radiation dose adsorbed at wrist and thorax by operators and detected by the electronic dosimeters
Time frame: During procedure
Radiation dose adsorbed by operators according to the radial access (right versus left)
Radiation dose adsorbed by operators according to the radial access (right versus left)
Time frame: During procedure
Radiation dose adsorbed by the patients
Radiation dose adsorbed by the patients
Time frame: During procedure
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.