Heart Failure (HF) with systolic dysfunction is associated with a poor prognosis in the long term despite the use of many effective drug treatment in reducing morbidity and mortality. In this context, cardiac resynchronization (CR), either alone or combined with a defibrillator function, has improved by about 30 to 40% of morbidity and mortality in this population of patients with heart failure. The information on the CR are now well established for patients with stage III-IV NYHA (New York Heart Association), with systolic dysfunction (EF ≤ 35%), presence of left bundle branch block wide (≥ 120 ms) and when medical treatment is optimal. As a result, the number of implanted devices continue to grow even if the implant procedures of cardiac resynchronization devices (CRD) are long, difficult and associated with significant complications with a risk of reoperation estimated between 10 and 15% . One of the most feared during implantation devices stimulation or defibrillation risk is represented by the risk of infection that will lead inevitably to explantation of the device. Despite the use of several preventive measures, including the use of an antiseptic shower, a local preparation for alcoholic povidone iodine (API) (PVPI 5% ethanol + 70%) and antibiotic prophylaxis clinical studies the most recent have clearly demonstrated that the risk of infection was associated with the duration of the intervention and was higher for procedures CR, it is noted in 2.4% in the short term and would be close to 3 to 4% in the medium term. Infections of implantable devices are associated with a poor prognosis, even in an excess mortality. It has been shown that the majority of infections may be linked to local contamination during surgery reinforcing the idea that prevention is mainly based on local measures and the reduction of operating time.
In this context, all measures that will reduce the risk of infection, will improve the prognosis of these patients. Thus, recent studies have shown greater effectiveness of local preparation for alcoholic chlorhexidine (applicator containing 2% chlorhexidine and 70% alcohol isopropanolol) (AC 2%) compared to the aqueous povidone iodine (API)in general surgery. It has been shown that the rate of local infection was significantly reduced in the AC group vs 2%. aqueous povidone iodine, respectively vs. 9.5%. 16.1% (p = 0.004). No randomized trials have previously prospectively compared the interest of local preparation with AC 2% compared with the usual preparation by API during implantation Resynchronization devices. Based on experimental and clinical studies, and we hope this new approach to assess local skin preparation in the prevention of general and local risk of infection after implantation of a cardiac resynchronization device. To ensure consistency, and because of its high efficiency assumed on the basis of experimental and clinical studies, the choice fell on the revenue 2% with applicator and patients should benefit from a primary location or "up-grading" to a CR device.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
2,272
CH d'Aix en Provence
Aix-en-Provence, France
CHU d'Amiens
Amiens, France
CHU d'Angers
Angers, France
CH d'Annecy
Annecy, France
CH d'Avignon
Avignon, France
CHU de Bordeaux
Bordeaux, France
CHU de Brest
Brest, France
CHU de Caen
Caen, France
CH de Chartres
Chartres, France
CHU de Clermont-Ferrand
Clermont-Ferrand, France
...and 14 more locations
Infection
Local or general infection in relation to the implantable device (skin erosion, externalization, local flow, local abscess, sepsis with or without bacteremia)
Time frame: 24 months
Cardiovascular event
Major cardiovascular events such as heart failure, embolic right heart.
Time frame: 24 months
Side Effects
Side effects attributable to local treatment.
Time frame: 24 months