SYMPHONY is prospective, multi-center, open-label, single-arm, Phase 3b psychometric validation study of the PAH-SYMPACT, a new quality of life questionnaire for patients with pulmonary arterial hypertension. Patients will be in the study for 5 1/2 months, 4 months of which they will receive macitentan, 10 mg, once daily. The primary objectives are to demonstrate the final content validity of the PAH SYMPACT instrument, to demonstrate the psychometric characteristics of reliability and construct validity of the PAH-SYMPACT instrument, and to demonstrate the ability of the PAH SYMPACT instrument to detect change. The secondary objective is to assess the safety of macitentan in patients with pulmonary arterial hypertension. The exploratory objective is to explore the effects of macitentan on PAH symptoms and their impact (as measured by the PAH-SYMPACT) in patients with pulmonary arterial hypertension.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
284
Macitentan tablet, dose of 10 mg, once daily
Cardiovascular Associates of the Southeast, LLC
Birmingham, Alabama, United States
University of Alabama at Birmingham
Birmingham, Alabama, United States
Pulmonary Associates, PA
Phoenix, Arizona, United States
Mayo Clinic Arizona
Phoenix, Arizona, United States
Cedars-Sinai Medical Center
Beverly Hills, California, United States
Development and Refinement of the Patient-reported Outcome Measure of Symptoms and Their Impact in PAH (the PAH-SYMPACT)
Content validity of the PAH-SYMPACT was assessed using item performance, exploratory and confirmatory factor analysis. The final item content and domain structure of PAH-SYMPACT was determined based on these analyses from the Steering Committee (expert clinicians) and findings from the qualitative research done with patients previously.
Time frame: From Screening Visit (Day -14) to End of Treatment (EOT) Visit (Visit 4, Week 16)
Validation of the Patient-reported Outcome Measure of Symptoms and Their Impact in PAH (the PAH-SYMPACT), With Reliability Assessed Via Test-retest Reliability.
The reliability of the PAH-SYMPACT is assessed by test-retest reliability. Intra-class correlation coefficients (ICCs) assess test-retest reliability for the symptom and impact part scores as well as domains. ICCs equal to or greater than 0.70 are considered to demonstrate good test-retest reliability for total and domain scores.
Time frame: From ePRO period 1 (Days -14 to -8) to ePRO period 2 (Days -7 to -1) in screening period.
Validation of the Patient-reported Outcome Measure of Symptoms and Their Impact in PAH (the PAH-SYMPACT), Assessing Internal Consistency Reliability.
The reliability of the PAH-SYMPACT is assessed by internal consistency reliability. This was determined using Cronbach's alpha-a value on an internal level scale from 0 to 1.0 with higher scores indicating a more-reliable (precise) instrument.
Time frame: From ePRO period 1 (Days -14 to -8) to ePRO period 2 (Days -7 to -1) in screening period.
Number of Participants With Treatment-emergent Adverse Events, Serious Adverse Events, and Adverse Events Resulting in Patient Study Drug Discontinuation Between Time Periods, BL to End of Study Visit (EoS, Week 16+30 Days for Follow-up Safety Visits)
Safety events are reported and documented as defined in study protocol.
Time frame: From Day 1 (Baseline Visit) to End of Study visit (EoS).
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
UCSF Fresno
Fresno, California, United States
UCSD Medical Center, Pulmonary Department
La Jolla, California, United States
VAGLAHS, VA Greater LA Healthcare System
Los Angeles, California, United States
University of California Los Angeles
Los Angeles, California, United States
University of California San Francisco Medical Center
San Francisco, California, United States
...and 71 more locations