Despite considerable effort the optimal site to place a pacemaker lead at the time of pacemaker implant remains unclear. Historically pacemaker leads have always been inserted at the bottom (apex) of the heart. It is suggested that a lead placed at the apex is associated with an increase in heart rhythm problems and also heart failure (impaired pumping function). The top of the ventricle (septum) has been investigated as an alternative site and is now routinely used by some centres. Previous estimation of the hearts pumping function (ejection fraction) has been limited to the use of echo (sound waves). Echo is not sensitive enough to detect small changes in the ejection fraction reliably (measure of pumping function of heart). The gold standard for measurement of ejection fraction is MRI (using magnets). Previous pacemakers have not been compatible with MRI scans. The latest generation of pacemakers are now able to be safely scanned within an MRI scanner. This allows a much more accurate estimation of the effects of a pacemaker on the ejection fraction which has not yet been studied. The investigators plan to study those patients undergoing a pacemaker implant and ablation procedure as part of their standard care. Individuals will have an exercise test, blood test used to measure biomarkers and fill in a symptom questionnaire. Individuals will have a Cardiac MR compatible pacemaker fitted and 2 ventricular leads will be inserted, one apically and one septally. Only one lead will be used at any given time. Individuals will then undergo their planned AV node ablation. Following this they will have a cardiac MR scan. Further MRI scans will be performed at 9 and 18 month intervals, as will symptom questionnaires, blood tests (BNP) to determine heart muscle strain, exercise testing and echocardiograms. The hypothesis is that a lead placed on the septum will produce superior cardiac performance over the short and long term.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
TRIPLE
Enrollment
53
Pacemaker set to pace at right ventricular apex initially.
Pacemaker set to pace at right ventricular septum initially.
MR conditional Pacemaker implanted in all study patients
University Hospital of South Manchester NHS trust
Manchester, United Kingdom
Ventricular Ejection fraction
Comparison of % change in Left and Right Ventricular Ejection Fractions between apical and septal pacing groups as measured on MRI.
Time frame: 18 months
Levels of BNP
Blood Sampling
Time frame: 18 months
MRI measures of Left and Right ventricular dyssynchrony
Time frame: 18 months
Exercise Capacity as measured by CPEX
Time frame: 18 months
6 minute walk tests
Time frame: 18 months
Quality of life measures SF36
Time frame: 18 months
Level of Pro-BNP
Blood sampling
Time frame: 18 months
Level of ICTP
Blood sampling
Time frame: 18 months
Level of MMP-1
Blood sampling
Time frame: 18 months
Level of MMP2
Blood sampling
Time frame: 18 months
Level of MMP-9
Blood sampling
Time frame: 18 months
Level of Troponin
Blood sampling
Time frame: 18 months
Level of GDF-15
Blood sampling
Time frame: 18 months