The purpose of this postmarket Registry is to assess the standard of care and clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System used in clinical routine according to the approved commercial indications. Procedures and assessments required by this registry are generally considered standard of care for Transcatheter Aortic Valve Replacement patients. Evaluation criteria will be the incidence of mortality/morbidity and adverse events clinical performance, and hemodynamic performance of the DEVICE via ultrasound (echo) and angiographic imaging.
The patient population will include patients who are candidates for transcatheter aortic valve replacement (TAVR). According to routine practice, the heart team (interventional cardiologist and cardiothoracic surgeon) makes a choice to use the Direct Flow Medical Aortic Valve System, compared to other available TAVR prostheses, on the basis of clinical and surgical considerations. Therefore, the valve is implanted when the heart team decides that this product is best suited to the specific patient. In order to be enrolled in this Registry, the patient must be a candidate for the implantation of the Direct Flow Medical Transcatheter Aortic Valve System, based on the commercial indications as stated in the Instructions for Use. Therefore, candidates for this study must meet the following criteria (Indications for Use): 1. Age \> 70 years old 2. Severe aortic valve stenosis determined by echocardiogram and Doppler: * mean gradient \>40 mmHg or peak jet velocity \>4.0 m/s AND * aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2 3. Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope). 4. Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20. All the Registry clinical evaluations and tests performed are generally considered standard of care for TAVR patients. When these recommendations conflict with the standard of care at the Registry site, the standard of care should prevail. In addition to the standard of care, the Sponsor recommends one brief additional evaluation (the EQ-5D quality of life measure) be conducted. Failure to perform this evaluation shall not be considered a protocol deviation. Baseline Clinical Evaluation * Medical History and Physical Exam * 12 lead ECG and Arrhythmia Assessment * Logistic EuroSCORE/STS Score * New York Heart Association (NYHA) functional status * Modified Rankin Score Assessment (mRS) * Current Cardiac Medications Baseline Imaging Studies * Transthoracic Echo (TTE) * CT Scan (ECG triggered, contrast enhanced) * Aorto-Iliac Angiogram: 1. Peripheral Evaluation 2. Coronary Evaluation All patients will have clinical follow-up at hospital discharge, 30 days, 12 months and annually to 3 years and undergo the following evaluations: * Physical Exam * 12 lead ECG and Arrhythmia Assessment * New York Heart Association (NYHA) functional status * Modified Rankin Score Assessment (mRS) if symptomatic for stroke * Current Cardiac Medications * Transthoracic echo (TTE) Patients in whom the heart team has planned to use the Direct Flow Medical Transcatheter Aortic Valve System valve, are informed of the DISCOVER Registry and their consent to participate is required. This study intends to monitor the clinical condition of the patient for a period of 3 years after the operation. By agreeing to participate, the patient agrees to undergo clinical assessments and specific tests at certain intervals (prior to the procedure; during the implantation; at hospital discharge, at 30 days after the procedure, and at 1 year, 2 and 3 years later); the patient also agrees to the collection of these daThe purpose of this Registry is to monitor outcomes data for the Direct Flow Medical Transcatheter Aortic Valve System in the Post Market phase. The primary outcome of interest is freedom from all-cause mortality at 30 days. The results from the pivotal CE mark study (IP 010) yielded a 30 day freedom from all-cause mortality rate of 97%. Should the "true" rate be 97%, then N=250 patients would provide an estimate of the rate with a margin of error of 2%, with 95% confidence.
Transthoracic Echo (TTE),CT Scan (ECG triggered, contrast enhanced),Aorto-Iliac Angiogram,Peripheral Evaluation,Coronary Evaluation,12 lead ECG,Arrhythmia Assessment, New York Heart Association (NYHA) functional status, Modified Rankin Score Assessment (mRS) if symptomatic for stroke, Current Cardiac Medications, Transthoracic echo (TTE)
Elisabeth Krankenhaus
Essen, Germany
RECRUITINGOspedale Niguarda Ca' Granda
Milan, Italy
RECRUITINGFreedom from all-cause mortality at 30 days
Time frame: 30 days
Device Success (VARC defined)
* Absence of procedural mortality AND * Correct positioning of a single prosthetic heart valve into the proper anatomic location AND * Intended performance of the prosthetic heart valve (no prosthesis-patient mismatch and mean aortic valve gradient \<20mmHg or peak velocity \<3m/s, AND no moderate or severe prosthetic valve regurgitation)
Time frame: 30 days
Early Safety
* All-cause mortality * All stroke (disabling and non-disabling) * Life-threatening bleeding * Acute Kidney Injury - Stage 2 or 3 (including renal replacement therapy) * Coronary artery obstruction requiring intervention * Major vascular complications * Valve-related dysfunction requiring repeat procedure (BAV, TAVR, or SAVR)
Time frame: 30 days
Clinical efficacy
* All-cause mortality * All stroke (disabling and non-disabling) * Hospitalization for valve-related symptoms or worsening congestive heart failure
Time frame: 30 days through 5 years
Clinical efficacy
• NYHA Class III or IV
Time frame: 30 days through 5 years
Clinical efficacy
• Prosthetic heart valve dysfunction (mean aortic valve gradient ≥20mm Hg, EOA ≤0.9-1.1cm2 \[depending on body surface area\] and/or DVI \<0.35, AND/OR moderate or severe prosthetic valve regurgitation)
Time frame: 30 days through 5 years
Time-related Valve Safety
• Structural valve deterioration: * Valve-related dysfunction (mean aortic valve gradient (mean aortic valve gradient ≥20mmHg, EOA ≤0.9-1.1cm2 \[depending on body surface area\] and/or DVI \<0.35, AND/OR moderate or severe prosthetic valve regurgitation) * Requiring repeat procedure (TAVR or SAVR)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Study Type
OBSERVATIONAL
Enrollment
1,000
Time frame: 5 years
Time-related Valve Safety
* Prosthetic valve endocarditis * Prosthetic valve thrombosis * Thromboembolic events (e.g., stroke) * VARC bleeding, unless clearly unrelated to valve therapy (e.g., trauma)
Time frame: 5 years