Epidural analgesia still have an impact on obstetric outcomes and especially on instrumented delivery rates. To assess the best maintainance regimen of epidural analgesia during labor the investigators plan to include 300 nulliparous in this multicenter randomized, double blind trial. The primary outcome will be a composite set of criteria that can lead to instrumented delivery. Secondary outcome will focus on analgesia motor block and satisfaction.
Patients will be informed during the anaesthetic consultation and recruited at the beginning of the labor if they comply with inclusion criteria. Habitual proceedings of the placing and induction of epidural analgesia (Local Anaesthetics (AL): Levobupivacaine 0.100% 15mL Sufentanil 10µg). Patients who will not obtain at 30min a pain score \< 1/10 will be excluded (epidural analgesia not functional). The upkeep of analgesia will be provided by an automatic pump and randomized in: classic pump and new pump. The mixture used will be the same in the 2 groups: Levobupivacaine 0.0100% + Sufentanil 0.5µg/mL. The classic pump administers AL with a continuous output (8mL/h)even though the new pump administers AL in bolus (8mL every hour; beginning 1h after the induction). The classic pump is a pump CADD SMITHS PCEA (Patient Controlled Epidural Analgesia) with the programming: continuous output 8mL/h; Additional bolus if necessary: 8mL; Maximal dose by hour: 24mL. The new pump is a pump CADD SMITHS called PIEB (Programmed Intermittent Epidural Bolus) with the programming: intermittent bolus 8mL every hour; Additional bolus if necessary: 8mL; Ban period during 10min between patient bolus and automatic bolus; Maximal dose by hour: 24mL. In case of the pain reappears and which is not calmed with 2 successive patient bolus, the anaesthetist will be called for the evaluation and administration of a doctor bolus if necessary (Levobupivacaine 0.125% 5mL associated with 50µg of Clonidine). Collected data will be demographic data, data about the obstetrical labor proceedings, data about pain, motor block, maternal satisfaction, total quantity of administered analgesia, number of patient and doctor bolus wich are asked and administered and neonatal data. Endpoints will be collected by a doctor in blind of the type of pump (the 2 pumps are the same extern aspect, only the intern programming is different). In case of caesarean during the labor, patient will be excluded of the study. When a decision of extraction will be taken, patient will receive a bolus of AL according to the anaesthetist decision but not accounted for the dose calculation.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
TRIPLE
Enrollment
304
Analgesia will be release by continuous manner with an automatic pump
Analgesia will be release by bolus with an automatic pump
Hôpital Mère Enfant
Bron, France
CHU d'Estaing
Clermont-Ferrand, France
CHU Bicêtre
Le Kremlin-Bicêtre, France
CHU of Montpellier
Montpellier, France
Occurence of a specific clinical criteria which can lead to a complication of the delivery
Specific clinical criteria are: * Type of posterior engagement * Type of posterior extrication * Duration of waiting at complete dilatation \> 3 hours * Duration of expulsive efforts \> 40 minutes * Foetal bradycardia \< 100 BPM during 1 minute at least
Time frame: Up to 10 hours
Instrumental delivery rate
Time frame: up to 10 hours
Pain during the end of labor
Time frame: up to 10 hours
Efficacity of epidural analgesia
Time frame: up to 10 hours
Efficacity of epidural analgesia
Efficacity of epidural analgesia is defined by a EVN score \< 3 at several times of delivery.
Time frame: up to 10 hours
Presence of motor block
Presence of motor block is estimated with Bromage and Straigh Raising leg scales.
Time frame: Up to 10 hours