The aim of the proposed study is to investigate the agreement between the measurement of the tongue diagnosis system (TDS) and the conventional way of tongue diagnosis about the tongue coating thickness (TCT) in the tongue diagnosis of the traditional Korean medicine (TKM).
Tongue diagnosis is one of the important diagnostic techniques to examine the physiologic functions and pathologic changes of the internal organs in TKM. However, traditional tongue diagnosis has inevitable limitations because of the clinician's subjectivity and environmental factors influencing on the diagnostic results. Therefore, it is necessary to investigate the availability of the tongue diagnosis system (TDS). The aim of the this study is to investigate the agreement between the measurement of TDS and the conventional way of tongue diagnosis about TCT in the tongue diagnosis of TKM. So, we will assess the agreement between the measurement of TDS and the final diagnosis of 5 clinicians with five or more years of clinical experience about TCT. Additionally, we will evaluate the reproducibility of TDS. In the 2nd visit, taking tongue images of each patient with TDS will be performed again at 30 minute-intervals in the same way. And then, we will compare the two TDS measurements of each patient about TCT. After twice examination of TDS, the weight of tongue coating (mg) will be measured quantitatively by tongue scraping to analyze the correlation between the weight of tongue coating and the measurements of TDS. In addition, after the collection of 60 patients' tongue images is completed, we will ascertain the validity of the five clinicians for diagnosing the TCT by assessing the inter-and intra-rater reliability of the five clinicians.
Study Type
OBSERVATIONAL
Enrollment
60
Kyung Hee University Korean Medicine Hospital
Seoul, Seoul, South Korea
RECRUITINGtongue coating thickness(TCT) by tongue diagnosis system
In the 2nd visit, Tongue coating thickness(TCT) will be assessed by tongue coating percentage(%)from TDS measurements. In the advanced study, 29.06% is a cut-off point to separate no coating and thin coating, and 63.51% is a cut-off point to separate thin coating and thick coating.
Time frame: 2nd visit (1st visit is for screening)
tongue coating thickness(TCT) by the five clinicians
After the collection of 60 patients' tongue images is completed, 5 clinicians with five or more years of clinical experience will assess the TCT of 60 patients with 60 images obtained by TDS. In order to decide the final diagnosis of the 5 clinicians as a gold standard, if we have a disagreement among them, we will agree to the views of the majority.
Time frame: After completing the collection of 60 patients' tongue images
the weight of tongue coating
The weight of tongue coating (mg); It will be measured quantitatively to analyze the correlation between the tongue coating percentage measured with TDS and the weight of tongue coating obtained by tongue scraping(Yaegaki's method).
Time frame: 2nd visit (1st visit is for screening)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.