The purpose of this study is to evaluate safety and tolerability of the ophthalmic solution PRO-156 over the ocular surface of ophthalmologically healthy volunteers
A phase I, open label and unicentric clinical trial to evaluate the safety and tolerability of the ophthalmic solution PRO-143 over the ocular surface of ophthalmologically healthy volunteers.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
30
Drug: PRO-156 ophthalmic solution One drop of PRO-156 ophthalmic solution administered to each eye, four times a day for 10 days.
Visual Acuity (VA)
The VA will be evaluated basally, without refractive correction with the Snellen chart. A Snellen chart is placed at a standard distance: 20 ft. At this distance, the symbols on the line representing "normal" acuity subtend. This line, designated 20/20 is the smallest line that a person with normal acuity can read at a distance of 20fs. the scale consists of 11 lines of letters of different size, the size of the letter gives a fractional value according to the visual acuity of the patient, the value is inversely proportional to the visual acuity, if the denominator is greater the visual acuity will be less. Line 1: 20/200 Line 2: 20/100, Line 3: 20/70, line 4: 20/50, line 5: 20/40, Line 6: 20/30, line 7: 20/25, Line 8: 20/20, line 9: 20/15, line 10: 20/13, line 11: 20/10. the results will be expressed as the mean of the denominator of the Snellen scale (scale 20/--) example. 18.5 ± 1.5, that means the final result is 20/18.5 ± 1.5
Time frame: 11 days
Intraocular Pressure (IOP)
The tension of a healthy eye should be between 10 and 20 millimeters of mercury (mmHg). In Goldman-type Applying Tonometry, the cornea is flattened, and the intraocular pressure is determined by measuring the force of application and the flattened area.
Time frame: 11 days
Number of Eyes With Epithelial Defects
the number of epithelial defects was evaluated by the application of fluorescein, Staining was performed with fluorescein which stained the degenerated cells and the mucus filaments present in the tear film.
Time frame: 11 days
Number of Cases With Adverse Events
The presence of adverse events was evaluated by the number of cases.
Time frame: 11 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.