This purpose of this study is to compare the clinical performance and subjective acceptance of two different daily disposable limbal ring lenses.
This is a subject-masked, dispensing study designed to evaluate the clinical performance and subjective acceptance when comparing two different daily disposable limbal ring lenses. Limbal ring lenses, which as well as correcting vision, have a colored ring which enhance the wearer's iris and are particularly popular in East Asian countries.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
30
contact lens
contact lens
Eurolens Research - The University of Manchester
Manchester, United Kingdom
Visual Acuity - Hema-copolymer and Etafilcon A
Visual acuity measured by logMAR of hema-copolymer and etafilcon A lenses assessed at baseline.
Time frame: Baseline
Visual Acuity - Hema-copolymer and Etafilcon A
Visual acuity measured by logMAR for hema-copolymer and etafilcon A lenses assessed at 1 week.
Time frame: 1 week
Biomicroscopy - Hema-copolymer and Etafilcon A
Biomicroscopy is analyzed for hema-copolymer and etafilcon A at 1 week. (Scale 0-4, 0=normal, 4=severe).
Time frame: 1 week
Lens Surface - Deposition - Hema-copolymer and Etafilcon A
Lens surface of deposition for hema-copolymer and etafilcon A pair of lenses assessed at baseline. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=absent, clean surface, 4= multiple deposits.
Time frame: Baseline
Lens Surface - Deposition - Hema-copolymer and Etafilcon A
Lens surface of deposition for hema-copolymer and etafilcon A pair of lenses assessed at 1 week. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=absent, clean surface, 4= multiple deposits.
Time frame: 1 week
Lens Surface - Debris - Hema-copolymer and Etafilcon A
Lens surface of debris for hema-copolymer and etafilcon A pair of lenses assessed at baseline. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=no debris present, 4=debris present more than two thirds of area beneath lens.
Time frame: Baseline
Lens Surface - Debris - Hema-copolymer and Etafilcon A
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Lens surface of debris for hema-copolymer and etafilcon A pair of lenses assessed at 1 week. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=no debris present, 4=debris present more than two thirds of area beneath lens.
Time frame: 1 week
Lens Surface - Wettability - Hema-copolymer and Etafilcon A
Lens surface of wettability for hema-copolymer and etafilcon A pair of lenses assessed at baseline. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=fully wetting lens surface, 4=presence of one or more non-wetting areas.
Time frame: Baseline
Lens Surface - Wettability - Hema-copolymer and Etafilcon A
Lens surface of wettability for hema-copolymer and etafilcon A pair lenses assessed at 1 week. (Each pair of lenses worn by the participant was assigned a single grade). Overall score measured by Grade 0-4; 0=fully wetting lens surface, 4=presence of one or more non-wetting areas.
Time frame: 1 week
Lens Fit - Horizontal Centration - Hema-copolymer and Etafilcon A
Lens fit of horizontal centration for hema-copolymer and etafilcon A lenses assessed at baseline. Overall score measured by extremely nasal, slightly nasal, optimum, slightly temporal, extremely temporal
Time frame: Baseline
Lens Fit - Horizontal Centration - Hema-copolymer and Etafilcon A
Lens fit of horizontal centration for hema-copolymer and etafilcon A lenses assessed at 1 week. Overall score measured by extremely nasal, slightly nasal, optimum, slightly temporal, extremely temporal
Time frame: 1 week
Lens Fit - Vertical Centration - Hema-copolymer and Etafilcon A
Lens fit of vertical centration for hema-copolymer and etafilcon A lenses assessed at baseline. Overall score measured by extremely inferior, slightly inferior, optimum, slightly superior, extremely superior
Time frame: Baseline
Lens Fit - Vertical Centration - Hema-copolymer and Etafilcon A
Lens fit of vertical centration for hema-copolymer and etafilcon A lenses assessed at 1 week. Overall score measured by extremely inferior, slightly inferior, optimum, slightly superior, extremely superior
Time frame: 1 week
Lens Fit - Corneal Centration - Hema-copolymer and Etafilcon A
Lens fit of corneal centration for hema-copolymer and etafilcon A lenses assessed at baseline. Overall score measured by extremely inadequate, slightly inadequate, optimum, slightly excessive, extremely excessive
Time frame: Baseline
Lens Fit - Corneal Centration - Hema-copolymer and Etafilcon A
Lens fit of corneal centration for hema-copolymer and etafilcon A lenses assessed at 1 week. Overall score measured by extremely inadequate, slightly inadequate, optimum, slightly excessive, extremely excessive
Time frame: 1 week
Lens Fit - Lens Movement - Hema-copolymer and Etafilcon A
Lens fit of lens movement for hema-copolymer and etafilcon A lenses assessed at baseline. Overall score measured by extremely inadequate, slightly inadequate, optimum, slightly excessive, extremely excessive
Time frame: Baseline
Lens Fit - Lens Movement - Hema-copolymer and Etafilcon A
Lens fit of lens movement for hema-copolymer and etafilcon A lenses assessed at 1 week. Overall score measured by extremely inadequate, slightly inadequate, optimum, slightly excessive, extremely excessive
Time frame: 1 week
Comfort Preference (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of comfort preference for hema-copolymer and etafilcon A assessed at baseline. Scale 0-100, 0=causes pain, 100= excellent.
Time frame: Baseline
Comfort Preference (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of comfort preference after insertion and before removal for hema-copolymer and etafilcon A lenses is assessed at 1 week. Scale 0-100, 0=causes pain, 100= excellent.
Time frame: 1 week
Vision Preference (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of vision preference for hema-copolymer and etafilcon A lenses assessed at baseline. Scale 0-100, 0=unacceptable, 100= excellent.
Time frame: Baseline
Vision Preference (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of vision preference for hema-copolymer and etafilcon A lenses assessed at 1 week. Scale 0-100, 0=unacceptable, 100= excellent.
Time frame: 1 week
Peripheral Blur (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of peripheral blur is assessed at baseline. Scale 0-100, 0=unacceptable, 100= excellent.
Time frame: Baseline
Peripheral Blur (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of peripheral blur assessed at 1 week. Scale 0-100, 0=unacceptable, 100= excellent.
Time frame: 1 week
Ocular Redness (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of ocular redness for hema-copolymer and etafilcon A lenses lenses assessed at 1 week. Scale 0-100, 0=extremely poor, 100= excellent.
Time frame: 1 week
Handling (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of handling (ease of insertion and ease of removal) for hema-copolymer and etafilcon A lenses assessed at 1 week. Scale 0-100, 0=unmanageable, 100= excellent.
Time frame: 1 week
Attractiveness (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of attractiveness for hema-copolymer and etafilcon A lenses assessed at baseline. Scale 0-100, 0=extremely poor, 100= excellent.
Time frame: Baseline
Attractiveness (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective Assessment of attractiveness for hema-copolymer and etafilcon A lenses assessed at 1 week. Scale 0-100, 0=extremely poor, 100= excellent.
Time frame: 1 week
Overall Impression (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective assessment of the overall impression for hema-copolymer and etafilcon A lenses assessed at baseline. Scale 0-100, 0=extremely poor, 100= excellent.
Time frame: Baseline
Overall Impression (Subjective Assessment) - Hema-copolymer and Etafilcon A
Subjective assessment of the overall impression for hema-copolymer and etafilcon A lenses assessed at 1 week. Scale 0-100, 0=extremely poor, 100= excellent.
Time frame: 1 week