The study is designed to validate the use of speckle-tracking echocardiography to measure tricuspid annular plane systolic excursion as a measurement of right ventricular function during transesophageal echocardiography.
1. Use of speckle-tracking echocardiography to validate tricuspid annular plane systolic excursion measurements with transesophageal echocardiography. 2. This study intends to validate the use of speckle-tracking echocardiography to measure the distance the tricuspid annulus moves during the systolic phase. The guideline articles regarding right ventricular function suggest m-mode measurements from the transthoracic approach and the same measurements may underestimate the actual distance on transesophageal echocardiography. This speckle-tracking technology will allow this distance to be measured despite its often non-parallel motion to the ultrasound beam, which otherwise limits the reliability of the valve recorded. 3. All subjects undergoing a planned surgical procedure in which the use of transesophageal echocardiography would be used regardless for their management. 4. No interventions, only evaluation of the measurements obtained with transthoracic echocardiography compared to transesophageal echocardiography. 5. No follow-up, study will be completed at the time of image acquisition.
Study Type
OBSERVATIONAL
Enrollment
112
All subjects will undergo both transthoracic echocardiography and transesophageal echocardiography to compare the results of measurements obtained from both imaging locations.
Unversity of Nebraska Medical Center
Omaha, Nebraska, United States
Speckle-tracking derived tricuspid annular plane systolic excursion with transesophageal echocardiography
Speckle-tracking derived tricuspid annular plane systolic excursion with transesophageal echocardiography
Time frame: 1 hour
M-mode derived tricuspid annular plane systolic excursion with transesophageal echocardiography
M-mode derived tricuspid annular plane systolic excursion with transesophageal echocardiography
Time frame: 1 hour
M-mode derived tricuspid annular plane systolic excursion with transthoracic echocardiography
M-mode derived tricuspid annular plane systolic excursion with transthoracic echocardiography
Time frame: 1 hour
Speckle-tracking derived tricuspid annular plane systolic excursion with transthoracic echocardiography
Speckle-tracking derived tricuspid annular plane systolic excursion with transthoracic echocardiography
Time frame: 1 hour
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.