The purpose of this study is to: * Compare PEEP level selected by individualized PEEP titration by electrical impedance tomography and PEEP level routinely used in post-operative cardiac patients with Hypoxemic Respiratory Failure; * Evaluate the agreement between the results of a rapid titration (total procedure duration = 5 min) versus an already validated slow titration (total procedure duration = 40 min) of the same patient, sequentially. Specifically, degree of collapse and degree of distention in each PEEP level, estimated by EIT; * Compare hemodynamics during the two maneuvers of PEEP titration; * Evaluate the efficacy of the selected PEEP (minimum PEEP preventing lung collapse less than 5%) to maintain stable levels of the following variables: arterial oxygenation, respiratory system compliance, and degree of collapse by EIT; * Compare these results (evolution of the three variables, along 4 hours) with the control strategy (default strategy currently used in the institution) group.
The acute respiratory distress syndrome (ARDS) increases the morbidity and mortality of patients admitted to the intensive care unit (ICU). In the postoperative period of cardiac surgery, the use of intraoperative extracorporeal circulation is one of the factors triggering the syndrome, its incidence increasing. Potentially, a protective ventilatory strategy with optimal positive end expiratory pressure (PEEP) could improve the prognosis of those patients with ARDS. An already validated maneuver to titrate the ideal PEEP to these patients has a longer duration, about 40 minutes. The lung Electrical impedance tomography (EIT) monitors respiratory system mechanics and intrathoracic lung volume changes and provides information about regional behavior and recruitability of lung tissue and thereby allows shortening titration maneuver, reducing its hemodynamic effects. Patients in the postoperative period of cardiac surgery with a diagnosis of Hypoxemic Respiratory Failure (PaO2/FiO2 \< 250 mmHg, calculated at FiO2 60%, and the presence of bilateral infiltrates on chest radiography), admitted to the surgical ICU from Heart Institute, University of São Paulo. Recruitment maneuver and PEEP titration maneuver will be monitored by EIT. All patients will be followed and monitored for 4 hours, with measures of the evolution of alveolar collapse . Hemodynamic and oxygenation data will also be recorded .
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
46
USP Instituto do Coração
São Paulo, Brazil
RECRUITINGTo test the agreement between the ideal PEEP determined by rapid titration versus and the ideal PEEP determined by the slow PEEP titration maneuver.
Evaluate the agreement between the ideal PEEP determined by the rapid PEEP titration maneuver versus the ideal PEEP determined by the slow PEEP titration maneuver. The degree of collapse and overdistention at each PEEP level, as estimated by EIT, will be also compared during both procedures. Ideal PEEP is the minimum PEEP capable of keeping collapse at \< 5%.
Time frame: 2 hours
Stability of the selected PEEP according to the rapid titration in arterial oxygenation (SpO2, in %), respiratory system compliance (in cmH2O), and degree of collapse by EIT (in %)
Evaluate the stability of the selected PEEP (according to the rapid titration), by analyzing the maintenance of three variables over a four hour period: arterial oxygenation, respiratory system compliance, and degree of collapse by EIT
Time frame: 4 hours