The initial treatment for most people with melanoma involves wide excision of the skin and sentinel node biopsy. As with other cancers, the status of the sentinel node provides important prognostic information to the patient and physician. Sentinel node biopsy was first developed using only a blue dye. Technetium99, a radioactive protein, was added later and provides the ability to image the patient and identify relevant lymph node basins. For the last 15 years or so, the standard method of SLN localization includes both tech99 and blue dye. While the rates of localization overall are excellent, these methods each have drawbacks. We are investigating a new method of finding sentinel nodes that uses a green dye that has an infrared signal. Our hypothesis is that indocyanine green (ICG) and real time lymphangiography is equivalent to technetium99 and methylene blue in identifying sentinel nodes (SLN) in patients with melanoma.
Patients with melanoma of the trunk or extremities were prospectively enrolled in this trial. Patients with head and neck melanoma were excluded from this study based on our pilot experience. ICG is poorly visualized through muscle, and there seems to be high background uptake in the parotid gland; both of these features limit the utility of ICG and fluorescence imaging. All subjects had T1b or greater melanoma, and met current National Comprehensive Cancer Network (NCCN) guidelines for sentinel node biopsy. All subjects had injection of tech99 and lymphangiography prior to surgery, and injection of indocyanine green (ICG) and methylene blue dye (MB) in the operating room. We utilized methylene blue dye for all subjects due to poor availability of isosulfan blue for a period of time, and to maintain consistency in the trial. Up to 1ml of MB was injected, and 0.9ml ICG (2.5 mg/ml). The ICG and MB were injected into the dermis separately, after induction of anesthesia and prior to prepping the patient. Each lymph node basin was examined with the gamma probe and imaged with the SPY Elite (Novadaq) prior to making skin incision, with assessment of the visibility of ICG through the skin (yes or no). Once incision was made, the basin was periodically imaged with SPY, or dissection was carried out with real time lymphangiography until the sentinel node was identified. The camera of the SPY machine is positioned over the basin, with the image projected onto a monitor. Similar to laparoscopy, the surgeon can watch the image and operate at the same time. Each sentinel node was assessed for the presence of each dye. A lymph node with any one of the dyes present was considered a sentinel node, and was resected. Fluorescence and blue dye were measured as yes or no, and not quantitated. Additional data collected includes demographic data, the dose of ICG and MB given, adverse effects from any dye, the total number of sentinel nodes identified and the number of malignant sentinel nodes. Pair-wise comparisons were made between the three dyes regarding the number of detected sentinel nodes, and the number of detected metastatic nodes.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
89
Subjects receive 0.9ml of ICG subcutaneously about the primary melanoma. The ICG has an infrared signal that is detected with the SPY Elite system (Lifecell). The ICG travels through the lymphatics to the sentinel node.
Technetium99 is a standard, widely used radiopharmaceutical that is injected subcutaneoulsy about the primary melanoma site. Lymphoscintigraphy is performed to identify the draining nodal basin, and a gamma probe is used in the operating room to track the radioactive signal and find the sentinel node.
Subjects receive 0.5-2ml of methylene blue subcutaneously about the primary melanoma at the time of surgery. The sentinel node should turn blue, which is visible with the naked eye.
Penn State Milton S. Hershey Medical Center
Hershey, Pennsylvania, United States
Equivalence of ICG and Real Time Lymphangiography to technetium99 and Blue Dye in Localizing Sentinel Nodes
The primary outcome measure is the accuracy of indocyanine green (ICG) and real time lymphangiography to identify sentinel nodes (SLN) in patients with melanoma, compared to tech99 and methylene blue. Tech99 is considered the standard, for comparison. Accuracy is being determined by the number of sentinel nodes that are identified with ICG, compared to tech99 or methylene blue.
Time frame: 2 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.