The purpose of this study is to compare the diagnostic gain between 22G standard needle vs 19G Flex needles transduodenal punctures of masses of the pancreatic head.
The negative predictive value of fine needle aspiration under ultrasound endoscopy (EUS-FNA) for the diagnosis of solid pancreatic masses is about 70 - 80 % with the 22G standard needle. Pancreatic adenocarcinoma is known to have a severe prognosis and a low rate of survival even after curative surgery. The study of pancreatic solid tumors is one the main diagnostic problem present in the investigators daily practice. In most of non operated patients, EUS-FNA is the sole possibility to confirm the diagnosis of malignancy which is required to initiate chemotherapy and/or radiotherapy. To improve the performances of the EUS-FNA, new needles are now disposable either with a cutting window design (EchoTip ProCore-COOK Medical) or flexible 19G needle (19G Expect Flex - Boston-Scientific). The goal is to obtain more tissue material with the possibility of a histologic study without increasing the risk of the puncture which is very low (complications rate \< 1%). The problem concerns the lesion of the head of the pancreas requiring a trans-duodenal access for the puncture . In this position, the needle is very difficult to push out the operator channel and, in some cases, the puncture is quite impossible with stiff needles as "ProCore" or standard 19G. Thus, the interest of flexible 19G needle is to be used in difficult technical cases as transduodenal access for head pancreatic tumors, with a good safety and more efficacy than 22G needles.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
124
puncture of head of pancreatic solid mass with fine needle aspiration under endoscopic ultrasonographic control. randomization: puncture with either 22G needle or 19G flex needle
puncture of head of pancreatic solid mass with fine needle aspiration under endoscopic ultrasonographic control. randomization: puncture with either 22G needle or 19G flex needle
Hopital Saint Joseph
Marseille, France
accuracy of 19G Flex Expect needle in the histological diagnosis of pancreatic solid tumors of the head of pancreas
accuracy and diagnostic gain of fine needle aspiration under ultrasound endoscopy (EUS-FNA) for the diagnosis of solid pancreatic tumors of the head of pancreas: comparison between 19G Flex and 22G standard needles punctures.
Time frame: 10 days
morbidity
immediate per-procedure complications and delayed morbidity (up to day 30) side effects resulting of technical failure or dysfunction of the puncture ease of handling for the two needles (visual analogic scale)
Time frame: 2 minutes, up to day 30
quality of histology
quality of histological specimens obtained with the 2 types of needles (visual analogic scale)
Time frame: 10 days