Prognosis in patients with glioblastomas (the most aggressive high-grade glioma) remains unfavourable. Tools for improving brain tumor surgery, in particular for gliomas, are increasing. There seems to be an agreement that achieving extensive resections, when done safely without jeopardizing neurological function, improves survival. Ultrasound is currently used as a tool for providing 2D or 3D images for the purpose of tumor localization and resection control. For the use in resection control the resection cavity is filled with saline to provide acoustic coupling between the ultrasound transducer and tissue. However, attenuation of acoustic waves is very low in saline compared to the brain and this difference in attenuation is the cause of artifacts that may severely degrade the ultrasound images. Such artifacts are seen as high-intensity signal at the resection cavity wall and beyond, potentially masking small tumor remnants and generally making the interpretation of images more difficult. This research group has developed an acoustic fluid intended for use in the resection cavity instead of saline. Tests in laboratory measurements have shown that the fluid reduces artifacts and has the potential to enhance ultrasound image quality in brain tumor surgery. The investigators expect that the acoustic fluid will make it easier to detect small tumor remnants near the end of an operation, thus increasing success of glioma surgery. The purpose of this study is to test the fluid during surgery for histopathologically proven glioblastoma to assess safety and efficacy.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
15
filled into the operation cavity during surgery for glioblastoma
Department of Neurosurgery, St Olavs Hospital
Trondheim, Norway
adverse events
All adverse events registered but with special emphasis on: Intraoperatively -- epileptic seizures Immidiate postoperative -- hydrocephalus (MR images), imflammation of tissue that was in contact with AF (MR images)
Time frame: 1-72 hours
adverse events
All adverse events registered but with special emphasis on: hydrocephalus (MR images) inflammation (MR images)
Time frame: 1 month
adverse events
All adverse events registered but with special emphasis on: hydrocephalus (MR images), inflammation (MR images)
Time frame: 6 months
adverse events
All adverse events registered but with special emphasis on: unusual clinical events, neurological deterioration or reduced consciousness
Time frame: up to 6 months
image quality
during the operation * Qualitative score of ultrasound image quality (poor-medium-good) * Qualitative score of artefacts in ultrasound images (none-some-much)
Time frame: 1 day
image signal-to-noise ratio
after the operation: image analysis by quantitative measurements of signal-to-noise ratio (SNR)
Time frame: 1 day