Using of surgical blade may have less blood loss than unipolar electrocautery in Total Knee Arthroplasty (TKA).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
80
Using surgical blade all the time of surgery
Using electrocautery all the time except at skin incision
Orthopaedic department, Faculty of medicine, Thammasat university
Klongluang, Changwat Pathum Thani, Thailand
Blood loss
\- detected total blood loss from hemoglobin at 24,48 hours after surgery, maximum Hb drop and blood loss collected in radivac drain
Time frame: 48 hours
inflammation
determine inflammatory response with C-rective protein (CRP) at post-op 48 hours
Time frame: 48 hours
Knee function
measured with WOMAC
Time frame: 3 months
knee range of motion
Time frame: 3 months
complication
detected with wound dehiscence, wound infection
Time frame: 2 weeks