To evaluate reduction of fluoroscopy time/dosis and safety of atrial fibrillation ablation in patients with paroxysmal atrial fibrillation using fluoroscopy image integrated 3-dimentional electroanatomical mapping system, comparing to using 3-dimentional electroanatomical mapping system without fluoroscopy image integration
The novel fluoroscopic image integrated 3-dimentional electroanatomical mapping system is designed for minimizing the exposure to X-ray for physician, staff and patients. This randomized single-center study is to evaluate the reduction on fluoroscopy levels (time and dosis) in catheter interventional treatment of symptomatic, antiarrhythmic refractory paroxysmal atrial fibrillation using fluoroscopic image integrated 3-dimentional electroanatomical mapping system, comparing with using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. Patients with documented paroxysmal atrial fibrillation, who are going to receive a catheter interventional treatment to atrial fibrillation, will be randomized (1:1) into two groups after signing an informed consent. Group 1 (CARTOUNIVU): using fluoroscopic image integrated 3-dimentional electroanatomical mapping system. Group 2 (CARTO3): using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. The ablation strategies in both study groups are the same, including circumferential isolation of ipsilateral pulmonary veins (PV) and voltage map guided substrate modification. According to the randomization, the ablation procedure will be performed with or without fluoroscopic image integration. The primary endpoint of this study is the evaluation of reduction on fluoroscopy levels (fluoroscopy time and dosis) during atrial fibrillation ablation procedure. Secondary endpoints include complete isolation of the pulmonary veins, completely bidirectional block of linear ablation lines, total procedure time, ablation-related complications.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
80
Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude \< o.5 mV) will also be ablated.
Department of Electrophysiology, University of Dresden - Heart Center
Dresden, Saxony, Germany
Fluoroscopy time for each step of atrial fibrillation ablation procedure
Fluoroscopy time will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
Time frame: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
Fluoroscopy doses for each step of atrial fibrillation ablation procedure
Fluoroscopy doses will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
Time frame: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
Number of patients with adverse events as a measure of safety
Perforation, tamponed, phrenic nerve injury and oesophagus injury (patients will be screened for oesophagus injury for a month after atrial fibrillation ablation), etc.
Time frame: All patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.
Number of patients with a failure of reaching endpoints of procedure as a measure of efficacy
number of pulmonary veins/linear ablation lines has not been completely isolated/blocked at the end of the AF ablation
Time frame: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
Total time of atrial fibrillation ablation procedure as a measure of efficacy
procedure time (minute)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: up to 24 hours