Patients with persistent irregular heartbeats also called persistent atrial fibrillation usually have a lower probability of curing their arrhythmia with ablation with heat called radiofrequency then those with paroxysmal atrial fibrillation, as previous studies have shown. The emerging ablation with freeze(cryoablation) has not been studied for persistent atrial fibrillation but has been proven to be efficient in the paroxysmal type. We hypothesized that persistent atrial fibrillation will have a freedom of recurrence rate of 70% after use of cryoablation at one year of follow up.
This was a retrospective single center cohort study designed to assess the freedom from recurrence of atrial fibrillation in the sample of patients with long persistent atrial fibrillation. All patients who underwent cryoballoon ablation for atrial fibrillation at Staten Island University Hospital in the period ranging from January 2010 to 2013 were included in the study. Data was collected from the electronic medical record as well as from the physician's office records after Institutional Review Board approval of the protocol .Data collected included demographics, comorbidities pertaining to diabetes, heart failure, coronary artery disease, stroke occurrence, medications including antiarrhythmics and anticoagulants, procedural details including time of procedure and of fluoroscopy, vein ostial size, number of veins isolated, time to first recurrence after blanking period, complications of procedure and mortality. All patient identifiers were kept in a password protected computer.
Study Type
OBSERVATIONAL
Enrollment
62
. The goal was to isolate all 4 veins with application of cryoballoon on the ostium of the vein. A 28 mm balloon was used with centrifugal cooling system. The maximum temperature reached was between -45 C and -60 C to optimize irreversible isolation without causing extracardiac complications. A circular catheter (Achieve) was used to map electrograms in conjunction with the NavX ENSITE 3000, St Judes . Intracardiac ultrasound was used to measure the pulmonary vein diameter, check for intraoperative complications, determine complete occlusion of the vein by the balloon and guide transeptal puncture. . In each patient the left atrium was debulked by applying cryoballoon
A 28 mm balloon was used with centrifugal cooling system. The maximum temperature reached was between -45 C and -60 C to optimize irreversible isolation without causing extracardiac complications. A circular catheter (Achieve) was used to map electrograms in conjunction with the NavX ENSITE 3000, St Judes . Intracardiac ultrasound was used to measure the pulmonary vein diameter, check for intraoperative complications, determine complete occlusion of the vein by the balloon and guide transeptal puncture. In each patient the left atrium was debulked by applying cryoballoon to the left and right sides of the left atrial roof and cryoablation of the left lateral ridge from within the left atrial appendage.
Staten Island University Hospital
New York, New York, United States
Time to Recurrence of atrial fibrillation
Recurrent atrial fibrillation is defined as re occurrence of atrial fibrillation in episode of more than 3 seconds as documented by device monitoring., loop recorder, implanted devices or event monitor. Only episodes that reoccur after the blanking period of 3 month post ablation are considered as recurrence.
Time frame: within 1 year after the procedure
Procedural time
The procedure time will be plotted against the date the procedure is performed to assess the improvement in operator skill.
Time frame: 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.