This pilot study aims to establish that treatment with near infrared light (NIR) reduces diabetic macular oedema in patients suffering diabetic retinopathy by exerting a positive beneficial effect at retinal cellular level.
This pilot study aims to establish that treatment with near infrared light (NIR) reduces diabetic macular oedema in patients suffering diabetic retinopathy by exerting a positive beneficial effect at retinal cellular level. Diabetic retinopathy is a common cause of severe loss of vision and the most common cause of blindness in individuals between the ages of 20 and 65 years in developed countries.Swelling of the central retina or "macular oedema". Patients will be treated in an office clinic,three times a week for a treatment duration of 2 minutes per session, a total of 12 times over the duration of 4 weeks and will be assessed at 8 weeks to establish any change induced in retinal oedema. Safety follow up will be assessed at 3 and 6 months post treatment.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
21
Each NIR light treatment will consist of a 90 second exposure of the macula of the study eye to the Ellex Integre NIR laser with the patient fixating on the central aiming beam. The laser light beam is 4.5mm in diameter with a central masked area of 1.0 mm diameter containing the central fixation target. In this way the central macula will be spared in the event of an adverse effect of the laser, which we do not anticipate. The patient will be seated at the slit lamp laser delivery system and after the eye has been dilated and anesthetised with topical eye drops a standard fundus contact lens will be placed on the eye through which the post area pole will be visualised while the treatment is delivered. There will be 12 treatments administered over a 5 week period.
Sydney Eye Hospital
Sydney, New South Wales, Australia
Change in Measurement in Central Macular Thickness Measured by Spectral Domain Optical Coherence Tomography( OCT) at One Month
Change in measurement( in microns) in central macular thickness as measured by Spectral Domain Optical Coherence Tomography( OCT)
Time frame: Change from baseline in central macular thickness at one month
Change in Measurement in Central Macular Thickness Measured by Spectral Domain Optical Coherence Tomography (OCT) at Two Months
Change in measurement (in microns) in central macular thickness as measured by Spectral Domain Optical Coherence Tomography (OCT)
Time frame: Change from baseline central macular thickness at two months
Change in Total Macular Volume as Measured by Spectral Domain Optical Coherence Tomography at One Month.
The change in total macular volume was taken as the difference between the total macular volume as measured by Spectral Domain Optical Coherence Tomography at 1 month and the total macular volume at baseline
Time frame: Change from baseline total macular volume at one month
Change in Total Macular Volume as Measured by Spectral Domain Optical Coherence Tomography at Two Months.
The change in total macular volume was taken as the difference between the total macular volume as measured by Spectral Domain Optical Coherence Tomography at 2 month and the total macular volume at baseline
Time frame: Change from baseline total macular volume as measured by OCT at two months
Change in Logmar Best Corrected Visual Acuity (BCVA) at One Month.
Change in Logmar Best corrected visual acuity (BCVA) from 1 month to that measured at baseline
Time frame: Change from baseline BCVA measured at one month
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Change in Logmar Best Corrected Visual Acuity (BCVA) at Two Months
Change in Logmar Best corrected visual acuity (BCVA) from 2 month to that measured at baseline
Time frame: Change from baseline BCVA measured at two months