This is a prospective non-blinded case series involving the acquisition of a pair production PET/CT as soon as possible after an already performed Y-90 Sirspheres treatment of hepatic malignancy. It will be performed in addition to the standard Brehmsstrahlung SPECT scan. The sequence of the two scans in each case (PET/CT vs SPECT) will be determined by availability of the scanners at the time. However, it is intended that both be acquired on the day of the Y-90 treatment. The length of subject participation will be one year. The measures used will be mostly qualitative in nature, and will include: * Correlation with expected vs. achieved tumor coverage by the treatment * Correlation between treatment distribution depicted by Brehmsstrahlung scans vs. the Internal Pair Production PET/CT scans, to. * Detection of non-target embolization, where applicable, and qualitative comparison between the two modalities as to the conspicuity of the abnormality Qualitative methods will be used by the analysis of the obtained PET/CT images and comparing them to the Brehmsstrahlung SPECT images as previously described.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
SCREENING
Masking
NONE
Enrollment
9
Subjects will receive a PET/CT Scan in addition to SPECT imaging, from the level of the lower chest to the lower pelvis, typical of an abdominal CT, usually within 1-3 hours after Yttrium-90 treatment.
Jackson Health System
Miami, Florida, United States
Number of Subjects Whose Y-90 Based PET/CT (Positron Emission Tomography/Computed Tomography)Scans Detected Extrahepatic Non-target Embolization.
Number of participants with detected extrahepatic non-target embolization. A qualitative comparison between the two modalities (Y-90 PET/CT and Brehmsstrahlung SPECT) as to the conspicuity of the abnormality would have been conducted had any participant had that result.
Time frame: 12 months
Comparison Between Treatment Distribution Depicted by Tc99mMAA (Technetium-99m Macroaggregated Albumin) Brehmsstrahlung Scans vs. the Internal Pair Production PET/CT Scans.
Number of participants demonstrating a similar treatment distribution depicted by Tc99mMAA(Technetium-99m macroaggregated albumin) Brehmsstrahlung scans vs. achieved Y-90 distribution on the Internal Pair Production PET/CT scans.
Time frame: 12 months
Comparison of Y-90 PET/CT to Y90 SPECT
Number of participants with a similar Y90 distribution depicted on Post Y90 delivery PET/CT and SPECT modalities, specifically comparing Y90 distribution within the treated tumors.