The purpose of this study is to assess the performance of a system of intraoperative dynamic dosimetry during prostate seed implantation (brachytherapy) including its new elements, to evaluate and refine technical methods of using the system, as well as confirm its performance and accuracy.
The use of brachytherapy or implantation of radioactive sources into the prostate for adenocarcinoma has advantages over external beam radiation in that a very high dose can be delivered to the tumor while limiting the doses to the surrounding normal tissue (i.e., bowel and bladder). It is established that outcomes after treatment with brachytherapy are related to the technical quality of source placement within the gland. Accurate placement of the radioactive sources with achievement of optimum dose distributions within the prostate is key to the success of brachytherapy with regard to both killing tumor as well as minimizing toxicity. Due to factors such as deformations of the prostate during needle insertion, needle deviation from intended path during insertion, prostatic edema from needle trauma, and relaxation of tissues as well as source migration after needle removal, the actual source positions upon completion of the procedure may fail to accurately match their intended placement, resulting in variations from the idealized dosimetric plan. One way to overcome this complex problem is to have the capability of visualizing the sources once they are in the prostate and then continuously updating the dosimetric plan in real time. To this end, we have developed a mechanism whereby ultrasound and fluoroscopy are quantitatively integrated to allow for real-time visualization of source positions intraoperatively. A prior Phase I study performed by this group evaluated a prototype version of this mechanism, resulting in the successful treatment of 6 patients with true intraoperative dynamic dosimetry. Dosimetric outcomes within this cohort of patients was excellent, and the intraoperative doses predicted by the system more accurate than that predicted by the current standard method (ultrasound-based dosimetry).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
45
The SKCCC at Johns Hopkins
Baltimore, Maryland, United States
Procedure Time
Additional procedure time with the registered ultrasound and fluoroscopy system (RUF) in the intra-operative setting for implantation procedure
Time frame: at time of implantation procedure
Seed Reconstruction From Intra-operative Fluoroscopy
Number of patients with all seeds reconstructed from fluoroscopy
Time frame: up to 30 days post-treatment
Number of Participants With Seed Reconstruction Utilizing RUF Versus CT / Magnetic Resonance Imaging (MRI) Reconstruction
Number of participants with seed reconstruction with RUF versus CT fused with MRI doses for Prostate D90 (dose received by 90% of prostate)
Time frame: 30 days post-treatment
Impact of RUF System on Dosimetric Outcomes of Seed Placement as Assessed by Number of Patients With Prostate V100 of 95% or Greater
Number of patients with prostate V100 (the percent of the postimplant MR/CT-based prostate volume that received at least 100% of dose) of 95% or greater
Time frame: 30 days post-treatment
Mean Difference in D90 Between Intra-operative RUF and Standard CT/MRI Based Dosimetry
Mean difference of D90 (% of prescribed dose) between intra-operative RUF and standard CT/MRI based dosimetry
Time frame: Treatment - 30 days
Dosimetric Accuracy Comparison Between Pre and Post Ultrasound (US) Implantation Prostate Edema
Time frame: Treatment - 30 days
Quality of Life (QoL) Assessments
Change in Quality of Life measures based on International Prostate Symptom Score (range 0-35, higher score reflects lower quality of life), Sexual Health Inventory Score (1-25, lower score reflects lower quality of life), Epic-26 Bowel score (0-100, lower score reflects lower quality of life)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: baseline, 30 days post-implant, semiannually post treatment until year 2 and then annually until year 5
Prostate Specific Antigen (PSA) Outcomes
PSA biochemical failure-free survival at last follow-up visit
Time frame: up to 5 years