The primary purpose of this study is to investigate the safety and efficacy of bilateral DWT in subjects with POAG or OHT compared to active and sham controls. The secondary purpose of the study is to investigate the durability, repeatability, and does response of the same.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
35
Deep Wave Trabeculoplasty (DWT) is an investigational device intended to reduce IOP in patients with POAG or OHT. The DWT device applies focal mechanical oscillation (low amplitude, sonic frequency) to the surface of the eye proximate the limbal region and anterior to the trabecular meshwork (TM). Mechanical oscillation of the TM by the DWT device is believed to initiate a physiological cascade to restore function of the TM, increase the outflow of aqueous humor and thereby decrease the IOP. DWT involves 24 spot treatments applied around the limbal region on the ocular surface. Dose A refers to 10 second spot treatments.
Laser trabeculoplasty is the application of a laser beam to burn areas of the trabecular meshwork, located near the base of the iris, to increase fluid outflow. Selective laser trabeculoplasty (SLT) uses a Nd:YAG laser to target specific cells within the trabecular meshwork and create thermal damage.
Asian Eye Institute
Makati City, Philippines
Pacific Eye and Laser Institute
Makati City, Philippines
Percent decrease in IOP and change in dependence on IOP-lowering medications from baseline
Time frame: 6 months
Intra-procedural and post-procedural adverse events
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Same as DWT device dose A except 20 second spot treatments.
Same as DWT device dose A except device not applied to ocular surface.