ROCSS is a randomised controlled trial of the placement of a biological mesh at the site of stoma closure. Our hypothesis is that reinforcing the stoma closure site with a collagen mesh (Strattice®) is superior to the standard technique in preventing herniation at 2 years.
Closure of complex and contaminated abdominal wounds is challenging and carries risks, including wound dehiscence and incisional hernias. Use of biological meshes in these situations may provide a safe method of reducing these complications, especially long-term incisional hernias. ROCSS will use stoma site closure as a model for biological mesh placement during any difficult contaminated abdominal wall closures. Hernia at the site of stoma closure occurs in up to 30% of patients and is associated with adverse effects on quality of life. In up to 10% of cases, patients are submitted to complex re-operation which carries significant morbidity. Not all patients will report symptoms or undergo repair, as they do not wish to have a further major operation. Incisional hernias at the site of stomas closure form an important and well defined subgroup. If there is a measurable benefit from mesh insertion, elective use of a collagen mesh would warrant consideration in the closure of other difficult, contaminated abdominal wounds. This study will also provide useful information on the value of using a CT scan as an early diagnostic tool of herniation, which could then be used in future abdominal wall studies as a surrogate endpoint for clinical hernia. ROCSS aims to assess whether a biological mesh (collagen tissue matrix) reduces the incidence of clinically detectable stoma closure site hernias at two years compared to standard closure techniques. The primary outcome is Occurrence of clinically detectable hernias at two years post randomisation. Other outcomes include surgical re-intervention rate, surgical complications at 30 days post-operation and 1 year post-randomisation, quality of life and post-operative pain, cost-benefit analysis and radiological hernia rate at one year post-randomisation (an exploratory analysis will compare radiological hernia rate at 1 year with clinical hernia rate at 2 years to assess the value of using a CT scan as an early diagnostic tool of incisional hernias). Randomisation is 1:1 between Strattice® mesh vs. standard closure. The sample size for the trial is 560 (80% power, 10% dropout/crossover, 40% proportional reduction - 25% to 15%) and recruitment will be over 2 years from at least 30 centres. ROCSS will be a double blind (observer blind) randomised controlled trial with a CT scan at one year and clinical follow up at 2 years. Cost benefit analysis and quality of life analysis will be performed at 2 years. The sample size will be reviewed prior to reaching target and may be increased 790 (90% power, 20% dropout/crossover, 40% proportional reduction - 25% to 15%).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
790
The protocol preference is for the mesh to be placed intra-peritoneally fashion (i.e. below the peritoneum). Anchoring bites will be taken in four to six sites of peritoneum (e.g. using 2-0 PDS) and the mesh will be 'parachuted' into place. Once correctly placed, the fascia above will be closed using Prolene, PDS or Nylon (surgeon preference, but excluding Vicryl). Infiltration of up to 40ml 0.25% Marcaine for infiltration into the fascial layer is recommended. The remainder of the closure will be at the surgeon's discretion.
The non-intervention arm for fascial closure will be the preferred technique of the surgeon without mesh reinforcement. The fascia should be closed with Prolene, PDS or nylon sutures; Vicryl should not be used for the fascia. The remainder of the closure will be at the surgeon's discretion.
Rate of clinically detectable hernias at two years post-randomisation.
Time frame: Two years post-randomisation.
Radiological hernia rate at one year post-randomisation.
An exploratory analysis will also compare radiological hernia rate at 1 year with clinical hernia rate at 2 years to assess the value of using a CT scan as an early diagnostic tool of incisional hernias.
Time frame: One year post-randomisation.
Incidence of developing a symptomatic hernia evaluated at 12 and 24 months postrandomisation.
The clinical detection of hernias defined by palpable fascial defects, and global weaknesses around closed stoma sites without palpable fascial defects, will be recorded. Patient-reported hernia symptoms including a local lump or pain at the site of the stoma closure will also be collected.
Time frame: One and two years post-randomisation.
Surgical re-intervention rates at 2 years post-randomisation.
Time frame: Two years post-randomisation.
Surgical complications, including wound infections and seroma formation, at 30 days postoperatively and at 1 year post-randomisation.
Time frame: 30 days postoperatively, 1 year post randomisation
Quality of life assessed using EuroQol EQ-5D at baseline, 30 days post-operatively, 12 and 24 months post-randomisation.
Time frame: Baseline, 30 days post-operatively, one and two years post-randomisation
Pain assessed using a 100 point visual analogue scale at baseline, 30 days postoperatively, 12 and 24 months post-randomisation.
Time frame: Baseline, 30 days post-operatively, one and two years post-randomisation
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Hvidovre Hospital
Copenhagen, Denmark
Academisch Medisch Centrum
Amsterdam, Netherlands
Tameside General Hospital
Ashton-under-Lyne, United Kingdom
Royal United Hospital Bath
Bath, United Kingdom
Heart of England NHS Foundation Trust
Birmingham, United Kingdom
Queen Elizabeth Hospital
Birmingham, United Kingdom
Sandwell General Hospital
Birmingham, United Kingdom
Pilgrim Hospital
Boston, United Kingdom
Bristol Royal Infirmary
Bristol, United Kingdom
Broomfield Hospital
Chelmsford, United Kingdom
...and 25 more locations
Costs per hernia clinically detected at 2 years post-randomisation.
Time frame: Two years post-randomisation.
Two-year and long-term costs per additional quality adjusted life (QALY) year gained.
Time frame: Two-year post-randomisation