After institutional ethics board approval and written informed consent from parents, 197 children scheduled for routine genitourinary operation and in whom a LMA was indicated for anesthesia were included in the study. The size of the LMA was determined by choosing the size that was best matched with the auricle of the children. The results were compared with the standard method recommended by the manufacturer's weight-related guidelines. The patients were classified in different groups depending on the PLMA sizes determined by both methods. A kappa coefficient evaluated the agreement between both techniques.
Study Type
INTERVENTIONAL
Allocation
NA
Masking
TRIPLE
Enrollment
197
the sizes of the PLMA determined with the ear-based formula were compared with the sizes according to the manufacturer's weight-based formula
Yeditepe University Hospital
Istanbul, Kozyatağı, Turkey (Türkiye)
the sizes of the PLMA determined with the ear-based formula
we were to determine whether the size of the auricle could be used as a proxy for the appropriate size of the PLMA
Time frame: One year