This study aims to determine the average compliance of a patient under CPAP therapy for obstructive sleep apnea as well as the various factors that influence it.
Obstructive Sleep Apnea (OSA) is a frequent disease that affects 4% of the male population and 2% of the female population, with well known repercussions on the quality of life (daytime drowsiness, concentration issues, increased motor vehicle accidents, etc) and cardiovascular risk (increased risk of strokes, hypertension, diabetes, CAD, etc.). It is caused by an intermittent relaxation of the throat muscles during sleep, thus blocking the airways and leading to snoring and apnea. Treatment can involve diets and sports, sleep hygiene techniques, mandibular advancement devices. But the CPAP (continuous positive airway pressure) device remains the first line therapy for OSA. It is very effective at reducing apnea-hypopnea (AHI) and oxygen desaturation indexes (ODI), but poor compliance is often noticed, with only 46% of patients still using the device at 6 months. Despite numerous studies on the subject, very few have included a large number of patients(\>150) or long follow up time (\>1 year), or reached conclusive evidence concerning the factors that influence CPAP compliance. In order to determine these factors, the investigators have taken into account approximately 450 patients over a timeframe of 5 years who have used a CPAP device during the course of their disorder, and established a Kaplan-Meyer estimation of their survival function. The investigators have then used anthropometry (BMI, neck circumference, sex, age, etc.), polysomnography (Epworth score, AHI, ODI, sleep efficiency, etc.) and CPAP (pressures, leaks, etc.) data with a Cox regression in order to determine the factors that influence the compliance of a patient. The results will allow us to establish the average compliance of a patient under CPAP therapy, as well as the reasons leading to its termination, the factors predicting a decreased compliance and the consequences of stopping the treatment. This will allow us to set up multiple methods of improved follow-up in patients that are predicted recalcitrant to CPAP therapy.
Study Type
OBSERVATIONAL
Enrollment
450
Hotel Dieu de France Hospital
Beirut, Lebanon
Compliance time to CPAP
Survival study taking the noncompliance to CPAP treatment as an event
Time frame: 6 years
Predictive factors related to the patient for compliance to CPAP (Sociologic and economic status, medical co morbidities, Anthropometric characteristics)
Factors related to the patient: Sociologic and economic status, medical co morbidities, Anthropometric characteristics.
Time frame: 6 years
Predictive factors related to the provider for compliance to CPAP (Attitude of the provider (active, passive), consistency/quality of the follow up)
Factors related to the provider: Attitude of the provider (active, passive), consistency/quality of the follow up.
Time frame: 6 years
Predictive factors related to the device for compliance to CPAP (Mask type, use of a humidification, Device type/mode, Pressure set, Cost, Side effects)
Factors related to the device: Mask type, use of a humidification, Device type/mode, Pressure set, Cost, Side effects.
Time frame: 6 years
Predictive factors related to OSA for compliance to CPAP (Severity score, fatigue and Epworth score, Polysomnography profile (AHI, ODI, Arousal index…), use of alternative treatments)
Factors related to OSA: Severity score, fatigue and Epworth score, Polysomnography profile (AHI, ODI, Arousal index…), use of alternative treatments.
Time frame: 6 years
Cardiovascular outcome/benefits (cardiovascular events; defined by hypertension, coronary event, stroke, diabetes, cardiac insufficiency, arrhythmias)
cardiovascular events; defined by hypertension, coronary event, stroke, diabetes, cardiac insufficiency, arrhythmias; timeframe: after CPAP cessation