The aim of the 3A Study is to assess the role of MetS on the arterial mechanics and vascular health in different age groups using the Cardio Ankle Vascular Index (CAVI) of the Vasera system and the "classic" carotid-femoral Pulse Wave Velocity (PWV).
Hypothesis The aim of thie 3A study is to assess the role of MetS on the arterial mechanics and vascular health in different age groups using the Cardio Ankle Vascular Index (CAVI) of the Vasera system and the "classic" carotid-femoral Pulse Wave Velocity (PWV). STUDY OBJECTIVES 1. Objectives Primary Objective: Assess the influence of MetS on CAVI values (primary study endpoint) in 3 different age groups (40-54, 55-69, 70-85 years) of a European population. 2. Secondary Objectives * Establish the CAVI values in a European population according to the clusters of (MetS) components i.e. cardiovascular risk factors: abdominal obesity, high triglycerides, low HDL cholesterol, elevated blood pressure (BP), systolic or diastolic, and elevated fasting glucose (and diabetes), as well as tobacco smoking. * Assess the correlation between CAVI and the carotid-femoral PWV in the full population and in each age group; and compare the impact of MetS and its components on both the CAVI and PWV * To establish, the relationship between cardiovascular risk factors and the evolution of arterial stiffness as evaluated by CAVI and carotid-femoral PWV over a 2-year follow-up period. * To assess changes and predictive value of CAVI on organ damages and CV events during the follow-up period. * To assess 24h ABPM and its correlations and variations with the CAVI and PWV in patients with MetS and/or its different components. This is a multinational European prospective longitudinal study.
Study Type
OBSERVATIONAL
Enrollment
2,000
CAVI will be measured using the Vasera device (VS1500 n - Fukuda Denshi co, Japan). This device is easy to use and calculates automatically the CAVI. CAVI measurements will be performed according to the manufacturer Measurements will be performed after five to ten minute - period of rest in order to obtain a steady hemodynamic state and to limit measurements variability.
ISVH
Paris, France
Cardio-Ankle-Vascular Index
CAVI will be measured using the Vasera device (Fukuda Denshi co, Japan). This device is easy to use and calculates automatically the CAVI. CAVI measurements will be performed according to the manufacturer recommendations Measurements will be performed after five to ten minute - period of rest in order to obtain a steady hemodynamic state and to limit measurements variability. The details of the CAVI measurements are shown in a specific document, C.F. appendix Ankle Brachial Index (ABI): The Ankle Brachial Index (ABI) will be measured using the Vasera device (Fukuda Denshi co, Japan). This device will calculate the ABI automatically. ABI measurements will be performed according to the manufacturer recommendations Measurements will be performed after five to ten minute - period of rest in order to obtain a steady hemodynamic state and to limit measurements variability.
Time frame: 2 years
Pulse Wave Velocity
Measurement of PWV will be performed using a validated automatic device (Complior®, Sphygmocor®, and PulsePen®). The method of "simultaneous" recordings of the pulse waves from 2 different sites (carotid and femoral arteries) will be preferred. Because of the use of several devices, normalisation of the measurement values will be performed according to the European Experts recommendations.
Time frame: 2 years
Blood pressure Measurements
Blood pressure will be measured in clinic according to the European Society of Hypertension (ESH) guidelines. BP should be measured in a standardized fashion using equipment that meets certification criteria.
Time frame: 2 YEARS