The LighTouch device shines imperceptible red light into the skin and measures the light that comes back out using the method of Raman Spectroscopy. Some of this light is color shifted and some is not. Using a proprietary numerical recipe, the LighTouch device combines the signals in this remitted light and calculates hematocrit, glucose, protein and potentially other analytes. Thus the LighTouch device produces information without painful physical insult to the patient and can trend changes in these blood analytes in order to predict the need for intervention.
The leading preventable cause of death for all people between 18 and 45, world-wide, military or civilian is uncontrolled internal bleeding i.e. hemorrhage. (A. Sauaia et al, J. Trauma 38, 185-193 (1995)). Internal bleeding can be very difficult to reliably detect when there is no visible external injury and the rate of blood loss is not very rapid. Two known leading indicators of blood loss are fluctuations in hematocrit and blood protein concentration. Monitoring of either of these analytes requires a blood draw and at least 3-5 minutes to obtain a single measurement. The LighTouch device shines imperceptible red light into the skin and measures the light that comes back out using the method of Raman Spectroscopy. Some of this light is color shifted and some is not. Using a proprietary numerical recipe, the LighTouch device combines the signals in this remitted light and calculates hematocrit, glucose, protein and potentially other analytes. Thus the LighTouch device produces information without painful physical insult to the patient and can trend changes in these blood analytes in order to predict the need for intervention. Previous IRB approved clinical trials over the last 10 years demonstrated useful performance for blood glucose and now the hematocrit and protein analytes are ready to be tested. Since hematocrit and protein concentrations change during hemodialysis it provides an ideal model to monitor these fluctions over time and assess the precision and accuracy of the LighTouch device for these analytes. This technique will not affect the usual dialysis treatment in any way. The subject will place one finger into the machine for exposure to the incoming light signal and sensors within the machine will detect light scatter from specfic analytes such as hematocrit. Literally hundreds of individuals have experienced the LighTouch device since 1999 and there has never been an unpleasant response or adverse outcome. The system is analagous to having a laser pointer shining on one's finger-tip. The ultimate goal of this research is to develop the device into a reliable non-invasive measure of critical blood elements that can be determined at the patient's side.
Study Type
near infrared light will be shone upon a fingerbed capillary and light scatter measured using in vivo raman spectroscpy
University Dialsyis Center
Syracuse, New York, United States
correlation with actual measured hematocrit
Time frame: 2 hours during dialysis
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
OBSERVATIONAL
Enrollment
5