The frequency of preoperative cardiac ischemia and the 30-days postoperative mortality is much higher than previously assumed, with approximately 10 % of patients undergoing non-cardiac surgery suffering from postoperative myocardial injury. A recent danish study furthermore showed that patients treated with a high inspiratory oxygen fraction during surgery had a higher 1 year mortality compared with patients treated with a low inspiratory fraction. This was especially significant among patients undergoing cancer surgery. A possible explanation, is that a high oxygen fraction results in oxidative stress and endothelial dysfunction. With this randomized cross-over study we wish to investigate the effect of a high inspiratory oxygen fraction on the endothelial function among healthy male volunteers. The primary outcome is the endothelial function assessed by the EndoPat system. Secondary outcomes are changes in oxidative biomarkers. Heart rate variability (HRV) recordings will serve as a measure for the effect of oxygen on the autonomic nervous system.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
DOUBLE
Enrollment
25
UHKoge
Køge, Denmark
Endothelial dysfunction assessed by the EndoPat-system
Changes in baseline pulse-wave-amplitude (PWA) after ischemia-reperfusion from the baseline PWA measurement until 5 minutes after ischemia as a measure of altered endothelial cell function caused by high inspiratory oxygen fractions
Time frame: After 2 hours of preoxygenation
Heart rate variability (HRV) after ischemia-reperfusion as a measure of altered balance in the Autonomic nervous system
Time frame: Baseline measure conducted from baseline until 20 minutes of pre oxygenation. Secondary measures is conducted 20 minutes before withdrawal of the oxygen
Plasma-Malondialdehyde (MDA)
Time frame: Meaured at baseline, after 2 hours of oxygenation and after 30, 60, 120, 240 minutes after the EndoPat measure
Plasma-Arginine/Asymmetric dimethylarginine(ADMA)
Time frame: Meaured at baseline, after 2 hours of oxygenation and after 30, 60, 120, 240 minutes after the EndoPat measure
Plasma-Tetrahydrobiopterin
Time frame: Meaured at baseline, after 2 hours of oxygenation and after 30, 60, 120, 240 minutes after the EndoPat measure
Plasma-Advanced oxidation protein products (AOPP)
Time frame: Meaured at baseline, after 2 hours of oxygenation and after 30, 60, 120, 240 minutes after the EndoPat measure
Plasma-Ascorbate/Dehydroascorbate (AA/DHA)
Time frame: Meaured at baseline, after 2 hours of oxygenation and after 30, 60, 120, 240 minutes after the EndoPat measure