The main goal of our study is to assess the accuracy and reproducibility of continuous beat-to-beat cardiac output (CO) measurement using pulse wave transit time in patients undergoing off-pump coronary artery bypass grafting.
Using appropriate statistical methods the cardiac index values obtained via pulse wave transit time with esCCO system will be compared with traditional transpulmonary thermodilution technique.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
20
After the end of surgery in ICU the positive end-expiratory pressure (PEEP) test of 15 cm H2O for 300 seconds will be performed. Following PEEP test, the two-step fluid load test of 6 ml/kg balanced crystalloid solution will be performed sharing in two portions: Initial mini FLT (mFLT) of 1.5 ml/kg within 1 min (approximately 100 mL) followed by the registration of continuous CI and traditional fluid responsiveness parameters and the rest of standard FLT (4.5 mL/kg) within 5 minutes (approximately 350 mL) followed by transpulmonary thermodilution, registration of continuous cardiac index (CI) and classic fluid responsiveness parameters.
Dep. of Anesthesiology, Northern SMU
Arkhangelsk, Russia
Accuracy (between the method bias and angular bias) and precision (between the method standart deviation and radial limit of agreement) of esCCO cardiac output measurement
Mean bias and standard deviation according to Bland-Altman analysis and angular bias and radial limit of agreement according to polar plot analysis for cardiac output assessed using pulse wave transit time in comparison with transpulmonary thermodilution
Time frame: Up to 24 hrs post surgery
Ability of augmented PEEP test (changes in cardiac output in response to an increase in PEEP) for predict the fluid responsiveness (changes in cardiac output in response to fluid load) in the early postoperative period
Prediction of changes in cardiac output in response to fluid load in early postoperative period of off-pump CABG using the assessment of reaction of cardiac output to an increase in PEEP. Evaluation of correlation and ROC curve.
Time frame: Immediate postoperatively
Ability of mini fluid load test (changes in CO in response to fast injection of minimal fluid volume) to predict fluid responsiveness (changes in CO in response to injection of standard fluid volume) in the immediate postoperative period following OPCAB
Prediction of changes in cardiac output in response to fluid load in the immediate postoperative period following OPCAB using the assessment of reaction of cardiac output to an increase mini fluid load. Evaluation of correlation and ROC curve.
Time frame: Immediate postoperatively