ROTEM® sigma is a new thromboelastometric coagulation analysis system. The new system is fully automated allowing for a simple and safe operation compared to its predecessor model ROTEM® delta. Method comparison of ROTEM® sigma with predecessor model ROTEM® delta) - confirmation of equality. Confirmation of reference intervals of the ROTEM® systems.
The main innovation of ROTEM® sigma is the development of a sample handler and a cartridge allowing for a of full automated test operation. As in ROTEM® delta four different tests can be run simultaneously on the four channels of the analyser. Whereas the tests in ROTEM® delta are performed manually by pipetting a blood sample and liquid system reagents, in ROTEM® sigma the reagents are contained in freeze dried pellet form in a cartridge. Test operation is performed by inserting a cartridge and attaching a blood sample to the analyser. The five available ROTEM® tests INTEM, EXTEM, FIBTEM, APTEM, and HEPTEM are contained in different combinations in two cartridge configurations: * Cartridge type 1 including INTEM, EXTEM, FIBTEM, APTEM * Cartridge type 2 including INTEM, EXTEM, FIBTEM, HEPTEM Aim of the study is the performance evaluation of the new ROTEM® sigma coagulation analyzer in comparison to the current ROTEM® delta thromboelastometry system. As a valid method comparison requires test results that cover the whole measurement range of the test system it is also necessary to include acute bleeding and emergency patients in the study. Only the inclusion of acute bleeding and emergency patients will produce strong pathologic test results allowing for a valid evaluation of the test system.
Study Type
OBSERVATIONAL
Enrollment
240
Group Healthy Volunteers: a blood sample is tested with ROTEM sigma Group Patients with expected coagulopathy: a blood sample is tested with ROTEM sigma and ROTEM delta in parallel
Florida Hospital Center for Thrombosis Research
Orlando, Florida, United States
NOT_YET_RECRUITINGUniversity of Maryland Medical Center
Baltimore, Maryland, United States
NOT_YET_RECRUITINGDepartment of Anesthesiology Weill Cornell Medical College New York-Presbyterian Hospital
New York, New York, United States
Method comparison: linear regression analysis and bias estimation at medical decision limits
Time frame: Parameter differences assessed at time of blood sampling