The purpose of this research study is to investigate if a new negative pressure incision (surgical cut) management system, could reduce the occurrence of groin wound infections after vascular surgery. This is a single use, sterile dressing that is applied to the patient's skin. It has an attached battery-powered unit that provides negative pressure (a vacuum environment) to the dressing and a disposable canister for the collection of wound fluids. The patient is being asked to participate in this study because the patient is planning to have a vascular surgery procedure that involves groin incision.
Surgical site infection (SSI) in groin wounds after vascular surgery is a significant contributing factor for increased morbidity. Despite the use of prophylactic systemic antibiotics, postoperative groin wound infection still occurs in some circumstances and it continues to be a serious problem after vascular surgical procedures. The incidence of SSI varies from 5 - 40%, and depending upon the depth of infection and type of vascular procedure, the morbidity could range from prolonged hospital stay to limb loss. Increased incidence of SSIs in patients is related to systemic factors like Diabetes, hypertension (HTN), history of smoking, chronic obstructive pulmonary disease (COPD), and local factors like disruption of lymphatics, groin proximity to the perineum, previous surgery at the same site and the use of prosthetic graft material. Prophylactic systemic antibiotics have been routinely used in all vascular surgery procedures, and despite of gentle tissue handling, proper hemostasis and other technical points to minimize tissue trauma, SSIs do happen. The investigators hypothesize that using a closed dressing system with negative pressure will keep the surgical site protected from nearby contaminated field and decrease the risk of infection
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
9
The PIMS unit is a single patient use, battery-powered, disposable unit that delivers continuous negative 125 mmHg pressure to the closed surgical incision for a 7-day therapy period. It is an easy to use device that also provides audible and visual alerts for low battery, maximum canister volume, and leak conditions. Additional alerts include system error and device life-cycle expiration (8 days). It is contained in a water-resistant housing, which allows the Subject to lightly shower with the device. Wound fluids are contained within the 45 mL canister. For the purposes of this clinical investigation, canisters can be replaced as often as is needed. A carrying case is also provided with the therapy unit, to allow for patient mobility during the therapy period.
North Shore-LIJ Health System
Lake Success, New York, United States
Incidence of Wound Infection With Szilagyi Grade
This study was terminated prior to gathering of data.
Time frame: 30 days
Assess the Safety of the Devise by Monitoring Incidence of Bleeding , Seroma Formation
This study was terminated prior to collection of data.
Time frame: 30 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.