International, multicenter, epidemiological study to demonstrate the correlation and predictive value of lyso-Gb1 concentration with the clinical severity of naïve, initially non-ERT/SRT Gaucher disease type 1 and during the study ERT/SRT-newly started Gaucher type 1 patients and to correlate lyso-Gb1 concentration with the clinical improvement of ERT or SRT treated Gaucher type 1 and the clinical course of non-treated patients based on GD-DS3
Gaucher disease is an autosomal recessive inherited lysosomal storage disorder. The disease is caused by the hereditary deficiency of the glucocerebrosidase, a lysosomal enzyme that breaks down glucocerebroside into glucose and ceramide. To date a definitive diagnosis of Gaucher's disease can only be made applying biochemical testing measuring the reduced enzymatic activity of the beta-glucosidase together with genetic confirmation. Since numerous different mutations may be the cause of a particular lysosomal storage disease the sequencing of the entire beta-glucosidase gene is applied in Gaucher's disease in order to confirm the genetic diagnosis. The use of primary storage molecules as biomarker was assessed for glucosylceramide (Gb1) in plasma of Gaucher's disease patients and compared to the level of Gb1 in healthy individuals. In order to establish a sensitive and specific biomarker for GD, we compared mass spectra of the plasma of healthy controls and GD patients using HPLC and tandem mass spectrometry. Mass spectra that differed most between patients and controls were analysed in more detail. The resulting biomarker, which was patented in June 2011 (PCT/EP2012/002409), was lyso - Gb1. We identified this compound as a reliable, sensitive and specific biomarker for GD in a cohort of GD patients. Furthermore, in a pilot study we evaluated whether lyso-Gb1 is related to the specific genotypes and is reliable for long-term monitoring of the efficiency of therapy. The aim this study is therefore to investigate lyso-Gb1 as a long-term prognostic marker in naïve, non-ERT/SRT GD type 1 patients by monitoring over the course of 36 months.
Study Type
OBSERVATIONAL
Enrollment
299
University Hospital Center Mother Teresa
Tirana, Albania
Aristotle University of Thessaloniki, Ippokration General Hospital
Thessaloniki, Greece
Centre for Human Genetics
Bangalore, India
Shaare Zedek Medical Center
Jerusalem, Israel
Demonstrating the correlation and predictive value of lyso-Gb1 concentration with the clinical severity of naïve, initially non-ERT/SRT Gaucher disease type 1 and during the study ERT/SRT-newly started Gaucher type 1 patients
lyso-Gb1 will be analzyed via Liquid Chromatography Multiple Reaction-monitoring Mass Spectrometry (LC/MRM-MS) and compared to merged control. The LC/MRM-MS is performed on an ABSciex 6500 triple quadrupole mass spectrometer, coupled with a Waters Acquity UPLC.
Time frame: 48 month
Correlating lyso-Gb1 concentration with the clinical improvement of ERT or SRT treated Gaucher type 1 and the clinical course of non-treated patients based on GD-DS3.
lyso-Gb1 will be analysed over a period of 36 months via Liquid Chromatography Multiple Reaction-monitoring Mass Spectrometry (LC/MRM-MS) to demonstrate the course of the biomarker.
Time frame: 48 month
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Children hospital
Rabat, Morocco
Hopital d'Enfant
Rabat, Morocco
The Children's Hospital and the Institute of Child Health
Lahore, Punjab Province, Pakistan
Hospital Universitari de Bellvitge (planta 7.1)
Barcelona, Spain