* To evaluate the safety and efficacy of MiStent drug (sirolimus)-eluting stent system in the treatment of coronary heart disease (CHD) in patients with primary in situ CHD (de novo); * To evaluate operating performance of the MiStent drug (sirolimus)-eluting coronary stent system.
* The study will enroll a total of 428 cases of primary in situ coronary artery disease patients (all patients enrolled with a maximum of two target lesions in different blood vessels and maximum of 2 stents per lesion. If more stents are needed for implantation, stents with the same brand are required, and mixing brands is not allowed for each patient except for salvage with implantation of other brand of stents.) * Lesions with reference diameter of 2.5mm-3.5mm (by visual measurement) and with length ≤40mm (by visual measurement) will be selected, subjects meeting the inclusion and exclusion criteria and who agree to participate will be enrolled. * Prospective, single-blinded, multi-center, randomized, controlled clinical trial; * Patients with in situ primary CHD; * Clinical sites: up to 18; patients will be enrolled in a 1:1 ratio (i.e., 214 cases enrolled into each group, the MiStent stent group and TIVOLI stent group); * Clinical follow-up time points: 1 month, 6 months, 9 months, 12 months and yearly at 2-5 years post index procedure; * Angiographic follow-up at 9 months post index procedure; in-stent late lumen loss measured by quantitative coronary angiography (QCA) will be used as the primary efficacy endpoint for product evaluation; * In this trial, the collection, collation, statistical analysis and adjudication of all relevant clinical and angiographic data will be conducted by an independent coronary angiography core laboratory (CCRF Medical Technology Co., Ltd.), data management and statistical center, clinical events committee and clinical audit agency. All patients will be followed up for 5 years (by telephone or outpatient form), and the incidence of adverse events will be recorded to allow a more accurate and reliable evaluation of the long-term safety of the MiStentTM drug (sirolimus) eluting coronary stent system.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
428
Primary in situ coronary artery disease patients (all patients enrolled with a maximum of two target lesions in different blood vessels and maximum of 2 stents per lesion. Lesions with reference diameter of 2.5mm-3.5mm (by visual measurement) and with length ≤40mm (by visual measurement).
Primary in situ coronary artery disease patients (all patients enrolled with a maximum of two target lesions in different blood vessels and maximum of 2 stents per lesion. Lesions with reference diameter of 2.5mm-3.5mm (by visual measurement) and with length ≤40mm (by visual measurement).
The Third Xiangya Hospital of Central South University
Changsha, Hunan, China
The First Affiliated Hospital of Baotou University
Baotou, Inner Mongolia, China
In-stent late lumen loss (LLL)
Late lumen loss is the difference in millimeters between the diameter of a stented segment post-procedure compared with the follow-up angiogram at nine months
Time frame: 9 months post index procedure
Success rate of stent implantation (including device success, lesion success and clinical success);
Time frame: Baseline
Restenosis rate in-stent, at proximal and distal edges of the stent and in-lesion segments; and late lumen loss and percent diameter stenosis in lesion segments
Time frame: 9 months
Device-related clinical cardiovascular composite endpoints post index procedure, including cardiac death, target vessel myocardial infarction and clinical symptoms driven target lesion revascularization (i.e., target lesion failure [TLF])
Time frame: 30 days, 6 months, 12 months, and 2-5 years
Patient-related clinical cardiovascular composite endpoints post index procedure, including all-cause death (cardiac and non-cardiac), nonfatal myocardial infarction and any revascularization
Time frame: 30 days, 6 months, 12 months and 2-5 years
Incidence of ARC-defined stent thrombosis (definite, probable, possible stent thrombosis at early, late and very late periods)
Time frame: 30 days, 6 months, 12 months and 2-5 years
Drug-related adverse events of dual antiplatelet therapy (DAPT) post index procedure.
Time frame: 30 days, 6 months, 12 months and 2-5 years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Inner Mongolia People'S Hospital
Hohhot, Inner Mongolia, China
The First Affiliated Hospital of Inner Mongolia Medical University
Hohhot, Inner Mongolia, China
The Second Affiliated Hospital of Nanchang University
Nanchang, Jiangxi, China
The First Affiliated Hospital of Xi'An Jiaotong University
Xi'an, Shaanxi, China
Sir Run Run Shaw Hospital School of Medicine, Zhejiang University
Hangzhou, Zhejiang, China
The General Hospital of Shenyang Military Region
Area of Shenyang, China
Fu Wai Hospital, National Center for Cardiovascular Disease
Beijing, China
The First Hospital of Jilin University
Changchun, China
...and 6 more locations