90 preterm infants were randomly assigned to kangaroo care (skin-to-=skin, chest-to-chest) group (n=50) or control (remained in incubator, prone (n=40) for a pretest period of 2- 3 hours, then fed, then KC group was placed in KC and control group remained in incubator for a 2-3 hr test period. EEG measures of sleep, HR, and RR were taken. .
The neonatal intensive care unit (NICU) environment is not conducive to sleep, and infant sleep in incubators is fragmented. Sleep contributes to brain maturation so interventions to foster sleep are needed. During Kangaroo Care (KC) behavioral indicators of Quiet Sleep have been observed but, not confirmed by objective electroencephalographic (EEG) analysis.The purpose was to determine the effects of Kangaroo Care (KC) on EEG-based sleep using Nihon Koden polysomnography and cardiorespiratory patterns by comparing KC sleep to incubator sleep.. A randomized controlled study with 90 preterms (KC = 50; control = 40) in which KC infants received 2-3 hours of KC between feeds after a comparable pretest period in an incubator and control infants remained in an incubator during the 2-3 hour pretest and test periods. In the incubator infants were inclined, prone, and nested; in KC infants were inclined, prone, and chest-to-chest underneath a blanket. The medically stable preterm infants were a mean 32 weeks postmenstrual age.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
90
skin-to-skin, chest-to-chest placement of diaper clad preterm infant up against his mother's chest and covered by a receiving blanket folded into fourths for 2-3 hours from one feeding to the next.
UH hospitals
Cleveland, Ohio, United States
EEG-based sleep
Infants attached to EEG machine and Respiratory impedance plethysmography bands prior to beginning of pretest period and remainded on EEG until end of study
Time frame: 2-3 hours
Heart rates during pretest
Heart Rate was detected by Nihon Koden polysomnograph
Time frame: 2-3 hours of pretest
Respiratory rate during pretest
Impedance plethysmography belts attached to Nihon Koden polysomnograph machine
Time frame: 2-3 hours pretest
Heart rates during test
Heart rate was detected by Nihon Koden polysomnograph
Time frame: 2-3 hours of test
Respiratory rate during test period
Impedance plethysmography belts attached to Nihon Koden polysomnograph machine
Time frame: 2-3 hours test period