Despite the large therapeutic arsenal available since one decade allowing a strong reduction of inflammation process, rheumatoid arthritis (RA) patients claimed pain, fatigue, sleep problems and other quality of life outcomes. Fatigue reduction during TNF blockers therapy is lower than the strong reduction in RA disease activity. Furthermore, RA patients have higher prevalence of non-inflammatory pain than general population. Fatigue is a real major problem due to 50% of patients considered it as severe. This dissociation between disease activity and fatigue level suggests that fatigue is multifactorial. No consistent explanations for fatigue are currently available.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
50
ANS (sympathetic nervous system) parameters are measured by VistaO2 device in RA patients
Chu Saint-Etienne
Saint-Etienne, France
Ratio low/high frequencies of power spectral density of R-R intervals
Comparison of Ratio low/high frequencies of power spectral density of R-R intervals between RA patients with low fatigue and RA patients with high fatigue. Ratio low/high frequencies of power spectral density of R-R is measured by VistaO2 device.
Time frame: day1
Number of sleep apnea syndrome
Comparison of Number of sleep apnea syndrome between between RA patients with low fatigue and RA patients with high fatigue. sleep apnea syndrome is measured by VistaO2 device.
Time frame: day 1
Standard deviation of all R-R intervals (SDNN)
Comparison of Standard deviation of all R-R intervals (SDNN) between RA patients with low fatigue and RA patients with high fatigue. Standard deviation of all R-R intervals (SDNN) is measured by VistaO2 device.
Time frame: day 1
Total Power spectral density (PSD)
Comparison of Total Power spectral density (PSD) between RA patients with low fatigue and RA patients with high fatigue. Total Power spectral density (PSD) is measured by VistaO2 device.
Time frame: day 1
PSD of Lower Frequencies
Comparison of PSD of Lower Frequencies between RA patients with low fatigue and RA patients with high fatigue. PSD of Lower Frequencies is measured by VistaO2 device.
Time frame: day 1
PSD of High Frequencies
Comparison of PSD of High Frequencies between RA patients with low fatigue and RA patients with high fatigue. PSD of High Frequencies is measured by VistaO2 device.
Time frame: day 1
normalized value of the High and Low frequencies
Comparison of normalized value of the High and Low frequencies between RA patients with low fatigue and RA patients with high fatigue. normalized value of the High and Low frequencies is measured by VistaO2 device.
Time frame: day 1
Physical activity
Comparison of physical activity between RA patients with low fatigue and RA patients with high fatigue. Physical activity is measured by IPAQ score.
Time frame: day 1
quality of sleep
Comparison of quality of sleep between RA patients with low fatigue and RA patients with high fatigue. Quality of sleep is measured by PSQI score.
Time frame: day 1
depression
Comparison of depression level between RA patients with low fatigue and RA patients with high fatigue. Depression is measured by HAD, BDI and HDRS scales.
Time frame: day 1
Correlation between fatigue and Ratio low/high frequencies of power spectral density of R-R intervals
fatigue is measured with a visual analogic scale
Time frame: day 1