Patients are candidates for single-level Artificial Disc Replacement between C3 and C7 who suffer from cervical symptomatic degenerative disc disease. A maximum of 200 cases will be enrolled into the study. An 18-month recruitment period is planned with a 4-year postoperative follow-up period for each subject. Thus, it is anticipated that the study will require a minimum of 5.5 years. Patients will be assessed preoperatively, intraoperatively, prior to discharge and again at 6 weeks, 6 months, 1 year, 2 years and 4 years postoperatively from the date of surgery.
The activ C Disc Prosthesis pursues the goal of restoring the disc function, the geometry and motion of the cervical disc. Its concept is based on a ball and socket joint, anchored between adjacent vertebral bodies. The modular prosthesis comprises the following elements: an inferior CoCr plate component anchored in the endplate of the caudal vertebral body. The UHMWPE inlay is securely fixed in this inferior component. The second element is the superior CoCr component, which is anchored in the end plate of the cranial vertebral body. It forms a ball joint with the inlay of the inferior plate component. The activ C product range enables reconstruction of various disc heights as well as adaptation to the end plate sizes. Secure primary anchorage of the prosthesis to the vertebral bodies is achieved by convexly shaped superior end pla tes and fixation means (spikes and grooves on the superior end plate, a small keel on the inferior end plate), whereas secondary stability is facilitated by an osseointegrative Plasmapore® coating. The objective of the study is to collect outcome information on the Activ® C Disc Prosthesis.
Study Type
OBSERVATIONAL
Enrollment
210
Regional Hospital Liberec
Liberec, Czechia
Faculty Hospital Motol Prague
Prague, Czechia
University Hospital Motol
Prague, Czechia
Helsinki University Central Hospital
Clinical Outcome measured by the Neck Disability Index (NDI)
The primary endpoint of the study will be changes in the clinical outcome measured by the Neck Disability Index (NDI) as published by Vernon et. al.
Time frame: 4 years
Visual Analogue Scale (VAS) on severity of neck pain and arm pain (experienced in the pain-dominant arm)
Time frame: 4 years
Visual Analogue Scale (VAS) on frequency of neck pain and arm pain (experienced in the pain-dominant arm)
Time frame: 4 years
Adjacent segment degeneration
Time frame: 4 years
Postoperative angular motion on flexion/extension radiographs in the replaced segment
Time frame: 4 years
Complication rates (device related and non-device related)
Time frame: 4 years
Overall success rate
Time frame: 4 years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Helsinki, Finland
Charité Berlin
Berlin, Germany
Berufsgenossenschaftliche Kliniken Bergmannstrost
Halle, Germany
Katholisches Klinikum Koblenz
Koblenz, Germany
Universität Rostock, Abteilung Neurochirurgie
Rostock, Germany
Neurosurgery at Instituti Fisioterapici Ospitalieri IFO
Rome, Italy
Warrington District General Hospital