The main objective of the trial is to study the technical feasibility of the implantation of a new electrode Monocontact deep brain stimulation electrode in dystonia.
Deep brain stimulation (DBS) is a validated therapy for treating dystonia and other movement disorders. The main therapeutical target used for treating dystonic syndromes is the internal globus pallidum (GPi). Given the morphology and the topography of this nucleus and, based on the experience of an efficient therapy by using only one or two contacts out of the available four contacts of the standard DBS lead, we designed two new electrodes, one one contact-electrode and one two contact-electrodes, with the aim to limit side effects related to internal globus pallidum DBS and to provide a more homogeneous electric field around the electrode within the GPi and maintaining the same therapeutical outcome. The main objective of the trial is to study the technical feasibility of the implantation of a new one contact-electrode (Monopolar DBS Lead Model 09064-40cm) for treating isolated generalized/segmental dystonia or tardive dystonia. The second main objective of the study is to assess the safety of the implantation of the new device. The secondary objective is to explore the therapeutical effect of DBS using the new monocontact electrode and to study the electrical field generated around the monocontact electrode within the GPi. The study is prospective and patients are recruited from a Tertiary Movement Disorders Clinic. Seven subjects will be recruited for the study.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
7
Deep brain stimulation surgery with implantation of one contact-electrode deep brain stimulation electrodes bilaterally in the internal globus pallidum for treating dystonia
Chru Montpellier
Montpellier, France
Technical feasibility of new electrode implantation
The feasibility of the implantation is evaluated by stereotaxic frame placement, site of incision, burr hole size and location, technique for insertion, connection with the extension cables to the neurostimulator, measure of the impedances, duration of the surgery, MRI control for lead position, comparison of the artefacts of the leads with the artefacts of the standard electrodes.
Time frame: One year
Safety of new electrode implantation (evaluated by the occurence of side effects)
The safety of the implantation is evaluated by the occurence of side effects after the implatation and along the follow-up.
Time frame: One year
clinical effect of deep brain stimulation using one contact-electrodes (Burke Fahn Marsden's dystonia rating scale and the Toronto Western Spasmodic Torticollis Rating Scale)
Clinical change as measured by the decrease of the motor and disability of the patient (Burke Fahn Marsden's dystonia rating scale and the Toronto Western Spasmodic Torticollis Rating Scale).
Time frame: One year