The patients will be allocated to 2 groups: the ultrasound group and the clinical group. The correct position of the double lumen tube will be determined by ultrasound (Sonoscape S6®) for the patients of the one group (group U) and by clinical examination for the patients of the other group (group C). The correct placement will be verified by bronchoscopy (Pentax®). The two methods will be compared in terms of sensitivity and specificity. The main purpose of the study is to determine if the ultrasound can be used for determination of the correct placement of the left sided double lumen endotracheal tube
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
SINGLE
Enrollment
5
After placement of the left sided double lumen endotracheal tube, ventilation of both lungs will be verified by ultrasound (Sonoscape S6®). The ultrasound probe will be placed between the 2nd and 3rd intercostal space at the level of the midclavicular line parallel to the line. The probe will be slightly moved or tilted until the pleural line is identified. If lung sliding is identified then the ventilation of the lung will be considered adequate. The same procedure will be repeated for each lung alone, after lung separation is applied. Verification of the ultrasound findings will be performed by bronchoscopy (Pentax®). The depth of the tube will be adjusted according to the bronchoscopy findings until correct positioning is established.
After placement of the left sided double lumen endotracheal tube, ventilation of both lungs will be verified by auscultation of the upper lung fields. The same procedure will be repeated for each lung alone, after lung separation is applied. Verification of the ultrasound findings will be performed by bronchoscopy (Pentax®). The depth of the tube will be adjusted according to the bronchoscopy findings until correct positioning is established.
Anesthesia department; 424 Army General Hospital
Thessaloniki, Greece
Correct position of the tube (yes/no).
The anesthesiologist who will place the left-sided double lumen tube will determine if the position of the tube is correct according to the ultrasound or clinical findings.
Time frame: Within an average of 5 minutes after the placement of the double lumen tube
Correct position of the tube by bronchoscopy (yes/no).
After the assessment of the tube's position, a second anesthesiologist will verify the position of the tube by bronchoscopy.
Time frame: Within an average of 10 minutes after the placement of the double lumen tube.
Time needed
The total time passed from the beginning of laryngoscopy until the final verification of the tube's position.
Time frame: Within an average of 10 minutes after the placement of the double lumen tube.