The purpose of this trial is to evaluate the safety and efficacy of ReActiv8 for the treatment of adults with Chronic Low Back Pain when used in conjunction with medical management.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
204
ReActiv8 implanted and configured to deliver stimulation at a patient-appropriate level, and participants instructed to deliver stimulation in two 30-minute sessions per day.
ReActiv8 implanted and configured to deliver low stimulation, and participants instructed to deliver stimulation in two 30-minute sessions per day.
University of California, San Diego
La Jolla, California, United States
Responder Rate of Low Back Pain With No Increase in Pain Medications
Comparison of responder rates for low back pain VAS between Treatment and Control groups. The Primary Efficacy Endpoint is a comparison of responder rates between Treatment and Control groups, where a "responder" is a participant with ≥30% reduction from baseline in average low back pain VAS, without any increase from baseline in pain medications and/or muscle relaxants for any reason including non low back pain reasons. The instrument used for evaluating pain is the continuous Visual Analog Scale (VAS) comprised of a horizontal line 10 cm in length, anchored by 2 verbal descriptors, where zero indicates no pain and 10 indicates worst imaginable pain. The value reported is a 7-day average low back pain. Any increase in dosage of a pain medication or any new pain medication taken for any reason counts as an increase in medications.
Time frame: 120 Days
Mean Change in Low Back Pain VAS
Comparison of change in LBP VAS (120 days from baseline) between the Treatment and Control groups. The instrument used for evaluating pain is the continuous Visual Analog Scale (VAS) comprised of a horizontal line 10 cm in length, anchored by 2 verbal descriptors, where zero indicates no pain and 10 indicates worst imaginable pain. The value reported is a 7-day average low back pain. A change to a lower score (negative value) indicates improvement.
Time frame: 120 Days
Cumulative Proportion of Responders Analysis (CPRA) for the Primary Endpoint to Compare Participants Responses Over a Full Range of Response Levels
The CPRA, which was prespecified in the clinical protocol and statistical analysis plan prior to the start of the trial, was performed using the same data as used for the primary endpoint analysis and was included as part of the primary endpoint analysis
Time frame: 120 Days
Serious Device and/or Procedure Related Adverse Event Rate
The primary safety assessment is of serious device and/or procedure related adverse events in all participants at 120 days. The 8 events reported below are 6 implant site pocket infections, 1 intra-operative upper airway obstruction, and 1 non-radicular, focal numbness on the surface of the thigh.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
The Spine Institute
Santa Monica, California, United States
University of Colorado Hospital
Aurora, Colorado, United States
Indiana Spine Group
Carmel, Indiana, United States
OrthoIndy
Indianapolis, Indiana, United States
University of Kansas Medical Center
Kansas City, Kansas, United States
The Brigham and Women's Hospital
Boston, Massachusetts, United States
Beaumont Health
Royal Oak, Michigan, United States
Duke University Medical Center
Durham, North Carolina, United States
Center for Clinical Research
Winston-Salem, North Carolina, United States
...and 16 more locations
Time frame: 120 Days
Change in Oswestry Disability Index (ODI)
Comparison of change in ODI (120 days from baseline) between Treatment and Control groups. ODI is reported as a score from 0 to 100%, where 0%-20% indicates minimal disability, 21%-40% indicates moderate disability, 41%-60% indicates severe disability, 61%-80% indicates crippled, and 81%-100% indicates bedbound or an exaggeration of symptoms. A change to a lower score (negative value) indicates improvement.
Time frame: 120 Days
Change in European Quality of Life Score on Five Dimensions (EQ-5D)
Comparison of change in EQ-5D (120 days from baseline) between Treatment and Control groups. The EQ-5D Index is scored on a scale of -0.594 to 1.00, with a score of 1.00 indicating full health. A change to a higher score (positive value) indicates improvement.
Time frame: 120 Days
Change in Percent Pain Relief (PPR)
PPR is a patient-reported percent of pain relief at 120 days compared to the pain at baseline, where 0% indicates no pain relief compared to baseline, and 100% indicates complete pain relief compared to baseline.
Time frame: 120 Days
Subject Global Impression of Change (SGIC)
A questionnaire completed with the following item: Since I enrolled in the study, my overall status is 1) Very much improved, 2) Much improved, 3) Minimally improved, 4) No change, 5) Minimally worse, 6) Much worse, 7) Very much worse
Time frame: 120 Days
Resolution of Back Pain (VAS ≤2.5 cm)
Resolution of back pain (remitter rate) was defined as a participant with 7-day average low back pain VAS ≤2.5 cm on the 10 cm VAS.
Time frame: 120 Days
LBP VAS Responder Rate at One Year
A "responder" is a participant with ≥30% reduction from baseline in average low back pain VAS, without any increase from baseline in pain medications and/or muscle relaxants for any reason including non low back pain reasons. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy.
Time frame: 1 Year
Mean Change in LBP VAS at One Year
Change in LBP VAS at 1 year compared to baseline. The instrument used for evaluating pain is the continuous Visual Analog Scale (VAS) comprised of a horizontal line 10 cm in length, anchored by 2 verbal descriptors, one for each symptom extreme for Low Back Pain. Zero indicates no pain and 10 indicates worst imaginable pain. The value reported is a 7-day average low back pain. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy. A change to a lower score (negative value) indicates improvement.
Time frame: 1 Year
Change in Oswestry Disability Index (ODI) at One Year
Change in ODI at 1 year compared to baseline. ODI is reported as a score from 0 to 100%, where 0%-20% indicates minimal disability, 21%-40% indicates moderate disability, 41%-60% indicates severe disability, 61%-80% indicates crippled, and 81%-100% indicates bedbound or an exaggeration of symptoms. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy. A change to a lower score (negative value) indicates improvement.
Time frame: 1 Year
Change in European Quality of Life Score on Five Dimensions (EQ-5D) at One Year
Change in EQ-5D at 1 year compared to baseline. The EQ-5D Index is scored on a scale of -0.594 to 1.00, with a score of 1.00 indicating full health. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy. A change to a higher score (positive value) indicates improvement.
Time frame: 1 Year
Percent Pain Relief at One Year
PPR is a patient-reported percent of pain relief compared to the pain at baseline, where 0% indicates no pain relief compared to baseline, and 100% indicates complete pain relief compared to baseline. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy.
Time frame: 1 Year
Subject Global Impression of Change (SGIC) at One Year
A questionnaire with the following item: Since I enrolled in the study, my overall status is 1) Very much improved, 2) Much improved, 3) Minimally improved, 4) No change, 5) Minimally worse, 6) Much worse, 7) Very much worse After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy.
Time frame: 1 Year
Resolution of Back Pain at One Year
Resolution of back pain (remitter rate) was defined as a participant with 7-day average low back pain VAS ≤2.5 cm on the 10 cm VAS. After the 120 day visit, participants crossed over to have their device programmed to deliver stimulation at a patient-appropriate level. At the one-year time point, participants in the Control/Crossover group have received 8 months of patient-appropriate therapy.
Time frame: 1 Year