The study is designed as a multi-center, international, prospective, parallel, randomized, single blinded trial comparing the time to first primary endpoint event (Sustained Paroxysmal AF/Persistent AF or stroke/TIA) occurrence in a follow up period of 3 years, between Closed Loop Stimulation (CLS) ON versus OFF, on top of a DDD pacing in patients with pacemaker or ICD indication who require dual-chamber pacing due to sinus node disease (SND), with or without atrioventricular (AV) block.
The benefits of rate-responsiveness on top of dual-chamber pacing still need to be definitively assessed in Sinus Node Dysfunction (SND). Although many rate responsive (RR) sensors have been developed, no large clinical trials evaluated their benefits in terms of clinical endpoints such as clinically relevant atrial fibrillation (AF) and stroke. Electromechanical sensors (piezoelectric accelerometers) have been widely used for their simplicity and overall reliability. However there is some evidence indicating the Closed Loop Stimulation as one of the more efficient and physiological sensors. Two randomized clinical studies have been conducted so far, showing that in the Brady-Tachy Syndrome the CLS algorithm was associated with a significantly lower overall atrial arrhythmia burden as compared both with a DDDR mode based on a standard accelerometric sensor and an atrial overdrive approach. Both studies yielded consistent results, albeit with a parallel and intraindividual comparison designs, respectively. The atrial arrhythmic burden is an important but surrogate endpoint, not necessarily related to long-term clinical outcome. The CLS effects on AF (if any) should be investigated in terms of time to first new onset of clinically relevant AF. In the light of these considerations, it appears interesting to run a large randomized study coherently collecting data on the overall clinical benefit of CLS, primarily in terms of AF and stroke, in a population indicated for pacemaker or ICD and needing dual-chamber pacing due to SND.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
1,390
First event of Sustained Paroxysmal AF or Persistent AF or stroke or TIA, whichever comes first.
Time frame: three years
Sustained Paroxysmal AF (SPAF)
Assess the date of each events of SPAF occurred during the follow-up periods
Time frame: Three years
Persistent AF
Assess the date of each events of peristent AF occurred during the follow-up periods
Time frame: Three years
Permanent AF
Assess the date when AF is declared permanent
Time frame: Three years
Stroke/TIA
Assess the date of each events of stroke/TIA occurred during the follow-up periods
Time frame: Three years
Worsening Heart failure Hospitalization (wHF-H)
Assess the date of each events of wHF-H occurred during the follow-up periods
Time frame: Three years
All cause mortality
Time frame: Three years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Wuhan Asia Heart Hospital
Wuhan, Jinghan District, China
The 2nd Affiliated Hospital of Harbin Medical University
Harbin, Nangang District, China
Xuanwu Hospital Capital Medical University
Beijing, West City District, China
Semmelweis University Heart and Vascular Center
Budapest, Hungary
Max Super Speciality Hospital
New Delhi, India
Ospedali Riuniti di Ancona
Torrette, Ancona, Italy
Ospedale Generale Regionale "F. Miulli"
Acquaviva delle Fonti, Bari, Italy
Ospedale "Bolognini"
Seriate, Bergamo, Italy
Presidio Ospedaliero Ospedale Sant'Anna
San Fermo della Battaglia, Como, Italy
Ospedale Civile SS. Annunziata
Savigliano, Cuneo, Italy
...and 44 more locations