Endoscopic radiofrequency ablation (RFA) is a new palliation therapy for malignant bile duct obstruction. It delivers a high amount of thermal energy to target tissue and may prolong the duration of stent patency. RFA has showed promising results for malignant bile duct obstruction and increasing the duration of stent patency. The aim of our study was to evaluate the feasibility and safety of endoscopic RFA for the treatment of bile duct obstructions, and to compare the efficacy of Endoscopic biliary RFA with the addition of self-expanding metal stents (SEMS) to SEMS alone in a randomized controlled trial.
Malignant bile duct obstructions are caused by many diseases arising from primary or metastatic disease in intrahepatic, extrahepatic or hilar locations. To relieve obstructive decompression and jaundice as a result of the obstruction, endoscopic stent placement is usually required. Compared with surgical intervention, stent insertion offers shorter hospitalization, lower overall cost and lower morbidity. Previous studies have shown the superiority of SEMSs over plastic stents for maintaining biliary drainage. However, SEMS can occlude due to epithelial hyperplasia, tumor in-/overgrowth, biofilm deposition and sludge formation. Studies have showed that the median SEMS patency is 120 days. Once bile duct obstruction reoccurs, it may lead to significant morbidity and mortality. Thus, long-term patency of the SEMS remains an unresolved issue. Recently, endoscopic biliary radiofrequency ablation (RFA) have been used in patients suffering from inoperable malignant bile duct obstruction, and increasing the duration of stent patency. It delivers a high amount of thermal energy to target tissue with curative or palliative intent. The purpose of this study is to record information and evaluate the impact of radiofrequency ablation in improving the management of cholangiocarcinoma or malignant bile duct obstruction, and to compare the effects of SEMS plus RFA to SEMS alone.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
100
The SEMS (Wallstent, Boston Scientific, USA) would be placed.
The RFA catheter has an 8 F bipolar probe and two ring electrodes 8 mm apart with the distal electrode 5 mm from the leading edge, providing local coagulative necrosis over a 2.5 cm length. The catheter is compatible with standard side-viewing endoscopes (3.2 mm working channel), and could be passed over 0.035 inch guidewires. Ablation was performed by using an RFA generator (1500 RF generator; RITA Medical Systems, Fremont, Calif) delivering electrical energy at 400 kHz set at 7-10 W for 90-120 seconds. The RFA energy can be delivered repetitively at different tumor sites within one procedure. After the RFA application is completed, SEMS (Wallstent, Boston Scientific, USA) can be deployed.
Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University
Nanjing, Jiangsu, China
RECRUITINGStent patency rate
Time frame: 6 months
Overall survival
Time frame: 3 years
Number of Participants with Adverse Events
Time frame: 30 days
Change from Baseline in Bile Duct Stricture Diameter
Time frame: 3 years