The purpose of this study is to determine whether electrical pudendal nerve stimulation is more effective than pelvic floor muscle training plus transanal electrical stimulation in treating post prostatectomy Incontinence.
Conservative therapy could be considered a choice of treatment for stress urinary incontinence (SUI) as it seems to have no side effect and causes significant and long-term improvement in symptoms. Pelvic floor muscle training (PFMT) and electrical stimulation are two commonly used forms of conservative treatment for SUI. PFMT improves the structural support of the pelvis. However, many patients have difficulty identifying and isolating their pelvic floor muscles (PFM) and are unable to perform the exercise effectively. Furthermore, patients who can identify the PFM often find that the required daily exercise routine is burdensome. Hence, the primary disadvantage of PFMT is lack of long-term patient compliance. Electrical stimulation (ES) is a non-invasive, passive treatment that produces a muscle contraction. Transanal electrical stimulation (TES) has little side-effect, and the patient compliance is 70-85% in published reports. TES results in PFM contraction by indirect nerve stimulation, mainly by polysynaptic reflex responses. The indirect stimulation and reflexive contraction may be the reason why the effect of electrical stimulation is not as good as that of PFMT when performed correctly. By combining the advantages of PFMT and TES and incorporating the technique of deep insertion of long acupuncture needles, we developed electrical pudendal nerve stimulation (EPNS). In EPNS, long acupuncture needles of 0.40 Х 100 or 125 mm were deeply inserted into four sacral points and electrified to stimulate the pudendal nerves (PN) and contract the PFM. CT transverse plane at the coccygeal apex has showed that the position of the lower needle tip is similar to where (adjacent to PN at Alcock's canal) the Bion device is implanted for chronic PN stimulation. Our previous study showed that EPNS had a better therapeutic effect on female SUI as compared with PFMT + TES. Simultaneous records of perineal ultrasonographic PFM contraction, vaginal pressure and pelvic floor surface electromyogram in our previous study have proved that EPNS can exactly excite PN and induce PFM contraction in female SUI patients. However, EPNS has also shown satisfactory effect in male patients with SUI problems. The purpose of this study is to compare the efficacy of EPNS to PFMT + TES in treating male SUI.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
96
Four sacrococcygeal points are selected. The two upper points are located about 1 cm bilateral to the sacrococcygeal joint. On the upper points, a needle of 0.40 Х 100 mm is inserted perpendicularly to a depth of 80 to 90 mm to produce a sensation referred to the root of the penis (perineum) or the anus. The locations of the two lower points are about 1 cm bilateral to the tip of the coccyx. On the lower points, a needle of 0.40 Х 100 or 125 mm is inserted obliquely towards the ischiorectal fossa to a depth of 90 to 110 mm to produce a sensation referred to the root of the penis (perineum). After the sensation referred to the above regions is produced, each of two pairs of electrodes from a G6805-2 Multi-Purpose Health Device is connected with the two ipsilaterally inserted needles.
A nerve function reconstruction treatment system (AM1000B; Shenzhen Creative Industry Co.Ltd, China) is used for EMG-biofeedback assisted PFMT.
Shanghai research institute of acupuncture and meridian
Shanghai, China
ICIQ-UI-SF
International Consultation on Incontinence Questionnaire-Urinary Incontinence-Short Form
Time frame: 8 weeks
diaper numbers
none, 1-3 per week, 4-6 per week, 1-4 per day and more than 4 per day are scored 0, 1, 2, 3 and 4 respectively
Time frame: 8 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
A neuromuscular stimulation therapy system (PHENIX USB 4,Electronic Concept Lignon Innovation, France) is used for TES