The purpose of this study is to determine if cholangioscopically-directed biopsies provide a higher diagnostic yield for malignancy in the setting of indeterminate biliary strictures when compared to standard means of sampling.
Biliary strictures in the absence of a mass are a clinical challenge, as current accepted means of sampling provide suboptimal accuracy. Both biliary brushings for cytology and fluoroscopically-directed biopsies produce highly-variable results. Endoscopic ultrasound with fine-needle aspiration has also been employed with variable results. An additional modality, using a single-operator cholangioscope during endoscopic retrograde cholangiopancreatography (ERCP) to obtain cholangioscopically-directed biopsies offers promise in increasing the yield of sampling. Initial observational studies have shown an improved diagnostic yield, but the technique has not been tested in a randomized, medical effectiveness study to better characterize its actual clinical impact. We aim to compare the technique of biopsy-on-biopsy derived sampling via single-operator cholangioscopy with standard fluoroscopically-directed biopsies and brushings in a pilot study. We also aim to perform a medical effectiveness study on the early use of single-operator cholangioscopically (SOC) in the evaluation of undiagnosed biliary strictures.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
3
The cholangioscopy procedure with the SpyGlass System is performed by a single operator with the SpyScope Access and Delivery Catheter positioned just below the operating channel of the duodenoscope. SpyBite Biopsy Forceps guided by the SpyScope Catheter are introduced and endoscopic-guided biopsy is taken at the level of the stricture. Target lesions will be identified under direct visualization using the SOC system, and 6-8 bites will be performed with the SpyBite forceps. Once SOC-directed biopsies are obtained, the SOC system will be withdrawn into the working channel of the duodenoscope and removed Patient will be contacted monthly to determine if they have undergone any additional procedures and to record potential adverse events.
Number of malignant diagnoses across hree-sample techniques (Spy bite, forceps biopsy, brushings)
Accuracy, sensitivity, and specificity of the three-sample technique (Spy bite, forceps biopsy, brushings) compared to the two-sample technique (forceps biopsy and brushing) in differentiating malignant from benign biliary strictures
Time frame: 72 Hours
Number of patients who receive additional diagnostic studies without receiving a cancer diagnosis
Patients who receive a repeat ERCP with sampling, cross-sectional imaging, EUS-FNA, IR-guided biopsies, laparoscopy
Time frame: 1 year
Endoscopic Satisfaction with SOC-directed biopsy
Endoscopist subjective outcomes using a Likert scale 1-5 * Ease of obtaining the biopsies * Confidence that the biopsy was taken from the target lesion * Confidence that an adequate sample was obtained from the biopsy * Clinical impression of malignant disease
Time frame: 2 hours
Time from procedure to the initiation of treatment (in cases of malignancy)
Time frame: 1 year