The purpose of this prospective single center study is to investigate if a developed algorithm is more accurate than the Broselow Tape (BT). For this study 500 patients are required to collect anonymized data (length, weight, age, anaesthesia material used during anaesthesia) for achieving a power of 80% during statistical analysis. The main hypothesis ist that the algorithm has a better accuracy than the BT.
This prospective single center study is performed at the university children's hospital zurich. Patients planned for surgery in general anaesthesia with intubation, aged 0 to 16 years and with a body length suitable for the emergency tapes can be included in this study. Patient and parental information is performed during the pre-anaesthetic visit. After written consent the patient will be included. Patient ́s length and weight will be measures earliest one day before data collection. Data collection during anaesthesia has no influence on the daily anaesthesia routine and has no impact on patient safety and anaesthesia. Patient's data is made anonymous for further inspection. Data is documented in Microsoft Excel and statistical analysis calculated with SPSS. 500 patients are needed for a power of 80%. Primary outcome parameter is length- based weight estimation, secondary outcome parameters are length-based age estimation and the correctness of recommended anaesthesia material (endotracheal tube, laryngeal mask, oropharyngeal mask and face mask). Both tools (algorithm and BT) will be compared with each other regarding primary and secondary outcome parameters.
Study Type
OBSERVATIONAL
Enrollment
312
Computer based comparison of the two devices based on collected patient data
University Childrens Hospital
Zurich, Switzerland
length-based weight-estimation by algorithm
The by the algorithm estimated bodyweight based on the patient's Body length is investigated regarding the estimations accuracy and cases in the +/- 10% interval
Time frame: during anaesthesia
length based age estimation
The by the algorithm estimated age based on the patient's body length is investigated regarding the estimations accuracy
Time frame: during anaesthesia
size of endotracheal tube
The by the algorithm suggested endotracheal tube based on the patient's Body length is investigated regarding the correctness
Time frame: during anaesthesia
size of laryngeal mask
The by the algorithm suggested laryngeal mask based on the patient's Body length is investigated regarding the correctness
Time frame: during anaesthesia
size of facemask
The by the algorithm suggested facemask based on the patient's body length is investigated regarding the correctness
Time frame: during anaesthesia
size of oropharyngeal tube
The by the algorithm suggested oropharyngeal tube based on the patient's Body length is investigated regarding the correctness
Time frame: during anaesthesia