The PACUS Trial was a single center, single blinded, randomized trial designed to evaluate the safety and efficacy of intravascular percutaneous catheter-delivered ultrasound energy to improve local Paclitaxel delivery effects in critical limb ischemia patients due to femoral-popliteal artery disease.
Study design The PACUS Trial was a single center, single blinded, randomized trial designed to evaluate the safety and efficacy of intravascular percutaneous catheter-delivered high intensity, low-frequency ultrasound utilizing CardioProlific Genesis™ System to improve local paclitaxel delivery effect in patients with CLI due to femoral-popliteal calcific lesions and occlusions. The protocol was approved by a Local Review Boards and the Institutional Ethics Committee. All patients provided written informed consent before enrollment. The trial was conducted in accordance with the declaration of Helsinki. Randomization Randomization occurred after successful crossing and pre-dilatation of the target lesion with a standard percutaneous angioplasty balloon without sub-intimal approach and/or flow limiting dissections. Patients were enrolled when a successful angiographic control was performed after PTA pre-dilatation. Subjects were randomly assigned by a computer-generated random sequence (2 blocks in a 1:1 ratio). Randomization was done in advance for all patients and without any stratification. The patients and physicians involved in the follow-up control were blinded to the treatment assignments through the completion of all 6 month follow-up evaluation. Operators were not blinded due to differences in treatment protocol. Twenty eight (28) patients were treated with an intravascular percutaneous catheter-delivered high intensity, low-frequency ultrasound and local Paclitaxel delivery with temporarily blood flow occlusion created by distal occlusion balloon (Study Group), and twenty eight (28) patients were treated with drug eluting balloon with conventional method (Control Group).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
56
Target lesion was exposed to 60 seconds of high intensity, low-frequency ultrasound generated by the Genesis™ system ( CardioProlific Inc., Hayward, CA). The ultrasound catheter is removed after the exposition.
Target lesion was treated with an angioplasty, performed using the INPACT Admiral drug eluting ballon (Medtronic)
Inflation of a 2 cm long balloon catheter Admiral (Medtronic) , located distally to the treatment area, in order to obtain a flow cessation
Number of patients with Freedom from clinically driven target lesion revascularization (TLR) and significant restenosis
Freedom from clinically driven target lesion revascularization (TLR) and significant restenosis as determined by digital subtraction angiography at 6 months follow-up
Time frame: 6 months follow up
Number of device and procedure related deaths and major adverse clinical events
Number of device and procedure related death and major adverse clinical events defined as stroke, myocardial infarction, need of surgical revascularization, distal embolization, recurrence of critical limb ischemia.
Time frame: 1 months follow-up
Percentage of Intraoperative Technical success
Percentage of Technical success (Patients with technical success/Total population) was defined as successful recanalization of the target vessel with ≤30% residual stenosis after the procedure
Time frame: Intraoperative
Number of participants with Clinically driven target lesion revascularization
Number of participants with Target lesion revascularization, defined as any repeat surgical or percutaneous interventions of the target lesion due to loss of patency as evaluated by DSA
Time frame: 12 months follow up
Number of participants with clinical improvement
Number of participants with Clinical improvement, defined as freedom from target limb amputation, target vessel revascularization, and increase in Rutherford class.
Time frame: 12 months follow up
Number of Death and major adverse clinical events
Number of death and major adverse clinical events included stroke, myocardial infarction, need of surgical revascularization, distal embolization, recurrence of critical limb ischemia.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Paclitaxel in a mixture with contrast medium at 1.0 µg/mm³ concentration was delivered to the treatment area for 60 seconds. The column of the Paclitaxel mixture filling the vessel was observed under the fluoroscopy and sustained during 60 seconds. The Paclitaxel /contrast medium mixture was then aspired with a 50 cc syringe and the distal balloon was deflated.
A final angiographic control was performed with injection of 10 cc of contrast medium and compared with the pre-procedural one.
Time frame: 12 months follow up